Triplett ET350 Assembly Instructions Manual Download Page 9

Storage 

temperature 

-20~50°C

Humidity 

≤80% (non-condensing) 

Altitude

 

<2000m 

Battery 

2x1.5V  AAA 

Product size 

6.3”x0.8”x1.0”(160.5x21.5x25 mm) 

Weight

 

About 

72g 

Drop test 

2m 

Battery Replacement 

1. Unscrew the battery cap
counterclockwise as shown below, and
then replace the batteries according to the
polarity indication.
2. Tighten the battery cap clockwise and
the buzzer will beep twice to indicate the completion of the
replacement.

Warranty Information 

Triplett / Jewell Instruments extends the following warranty to the original 

purchaser of these goods for use. Triplett warrants to the original purchaser for 

use that the products sold by it will be free from defects in workmanship and 

material for a period of (1) one year from the date of purchase. This warranty 

does not apply to any of our products which have been repaired or altered by 

unauthorized persons in any way or purchased from unauthorized distributors so 

as, in our sole judgment, to injure their stability or reliability, or which have been 

subject to misuse, abuse, misapplication, negligence, accident or which have 

had the serial numbers altered, defaced, or removed. Accessories, including 

batteries are not covered by this warranty 

Copyright © 2019 Triplett 

Summary of Contents for ET350

Page 1: ...After reading this manual it is recommended to keep the manual at an easily accessible place preferably close to the device for future reference The ET350 is a non contact voltage and magnetic field...

Page 2: ...fully understand the warnings and operating instructions before use 2 Please test the detector on a known live source within the rated AC voltage range before use 3 If the detector appears damaged or...

Page 3: ...13 The detector will not detect any voltage if The wire is shielded The operator is not connected with the ground or isolated from an effective ground The voltage is DC 14 The detector may not detect...

Page 4: ...ity of electric shock Warning Refer to the manual In compliance with the directive of European Union Panel Description Operating Instructions 1 Turning on the detector 1 NCV sensor head 2 Flashlight l...

Page 5: ...ress the flashlight button to turn on off the flashlight The flashlight will automatically turn off when the detector is not used for 5 minutes 3 AC voltage detection Place the sensor head near the te...

Page 6: ...eak electrical field environment c Short press the power button once again The green indicator light will switch to yellow and the device will switch to magnetic field detection mode Note In the magne...

Page 7: ...that the solenoid valve is working properly Note If the magnetic flux is less than 5mT please use the front of the detector tip to detect 6 Auto power off The detector will auto power off when it is n...

Page 8: ...en indicator Frequency range 50Hz 60Hz Alarm mode Audio visual Flashlight White spotlight Auto power off About 5 minutes Low battery indication Vibration function N A Magnetic field detection mode Yel...

Page 9: ...to the original purchaser of these goods for use Triplett warrants to the original purchaser for use that the products sold by it will be free from defects in workmanship and material for a period of...