Features 

Low voltage mode (24V AC ~ 1000V AC)  
Suitable for testing low-voltage motor (< 90V), audio systems, arc 
welding machines, underground mine lighting, cables with thick 
insulation layer, and other weak electromagnetic AC signals.  

High voltage mode (90V AC ~ 1000V AC): 
For detecting urban electric supply and three-phase systems. For 
example, power distribution units, electrical panels, and electrical 
appliances.     

Safety 

 

      Warning 
1. Please carefully read and fully understand the warnings and
operating instructions before use.
2. Please test the detector on a known live source within the rated AC
voltage range before use.
3. If the detector appears damaged or is not working properly, stop
using it immediately.
4. Do not detect voltage higher than 1000V.
5. Use caution when measuring AC voltage higher than 30V.
6. There may still be voltage even when no acousto-optic alarm is on.
7. The insulation type, wire thickness, distance from voltage source,
shielded wire, other wires, socket design, and other factors may
adversely affect test result. If there are uncertainties, use other
methods to verify the voltage.

Summary of Contents for ET350

Page 1: ...After reading this manual it is recommended to keep the manual at an easily accessible place preferably close to the device for future reference The ET350 is a non contact voltage and magnetic field...

Page 2: ...fully understand the warnings and operating instructions before use 2 Please test the detector on a known live source within the rated AC voltage range before use 3 If the detector appears damaged or...

Page 3: ...13 The detector will not detect any voltage if The wire is shielded The operator is not connected with the ground or isolated from an effective ground The voltage is DC 14 The detector may not detect...

Page 4: ...ity of electric shock Warning Refer to the manual In compliance with the directive of European Union Panel Description Operating Instructions 1 Turning on the detector 1 NCV sensor head 2 Flashlight l...

Page 5: ...ress the flashlight button to turn on off the flashlight The flashlight will automatically turn off when the detector is not used for 5 minutes 3 AC voltage detection Place the sensor head near the te...

Page 6: ...eak electrical field environment c Short press the power button once again The green indicator light will switch to yellow and the device will switch to magnetic field detection mode Note In the magne...

Page 7: ...that the solenoid valve is working properly Note If the magnetic flux is less than 5mT please use the front of the detector tip to detect 6 Auto power off The detector will auto power off when it is n...

Page 8: ...en indicator Frequency range 50Hz 60Hz Alarm mode Audio visual Flashlight White spotlight Auto power off About 5 minutes Low battery indication Vibration function N A Magnetic field detection mode Yel...