Function Buttons
MODE and Backlight Button
•
Press MODE and Backlight Button to select OHM/Diode/Continuity/CAP/LoZ
AC/DC Voltage.
•
Press the MODE and Backlight button for over 1 second to turn the button,
Knob and Rotary light on.
•
Press again for over 1second to turn the button, Knob, and Rotary light off.
MAX/MIN Button
•
Press MAX/MIN Button the maximum and minimum values are measured.
•
This mode is activated on each measurement except for continuity test, diode
test capacitance test and AUTO SENSE Voltage mode.
•
This mode is disabled keeping pressed MAX/MIN Button or moving the rotary
switch.
DATA HOLD and Flashlight Button
•
To freeze the LCD reading, press the HOLD and Flashlight Button.
•
While data hold is active, the HOLD icon appears on the LCD.
•
Press the HOLD and Flashlight Button again to return to normal.
•
Press the HOLD and Flashlight Button for over 1 second to turn the light on.
•
Press again for over 1second to turn the light off.
Automatic Power OFF
In order to conserve battery life, the meter will automatically turn off
after approximately 15 minutes.
To turn the meter on again, turn the function switch to the OFF
position and then to the desired function position.
To press and hold the
MODE and Backlight Button
to turn the