9
SPECIFICATIONS
DC Volts
Ranges:
0-3, 15, 60, 300 (20,000 ohms per volt)
Accuracy:
±
3% of full scale value
AC Volts
Ranges:
0-3, 15, 60, 300 (5,000 ohms per volt)
Accuracy:
±
4% of full scale value
(on 60Hz sine wave at 77
°
F)
Ohms
Ranges:
0-20K, 200K, 2 Meg, 20 Meg
(200, 2K, 20K, 200K @ center scale)
Accuracy:
±
3% of DC scale length
(with fully charged battery)
Ohmmeter Specifications:
Range
X1 X10 X100 X1K
Max Voltage
(Volts)
1.6 1.6 1.6 14.0
Max Current
(mA)
8.0 0.8 .08 .07
Max. Power
(mW)
3.2 .32 .032 .245
DC Milliamperes
Ranges:
0-.6, 6, 60, 600
Accuracy:
±
3% of full scale value
Burden Voltage (@ full scale)
:
Approx. 330mV on 600mA range
Approx. 250mV on other ranges
www.
.com
1.800.561.8187