Triogen TES18 Installation & Operating Instructions Manual Download Page 11

10

MAINTENANCE

UV LAMP THIMBLE CLEANING.

12 - After removing the plastic nut, the thimble water seal will be visible and 

should be removed and stored safely.

13 - Grip the visible end of the glass thimble and pull upwards until the thimble is

fully removed from the reactor body.

14 - If staining or deposits are present on the outer surface of the thimble then

these can be removed by mixing a mild solution of muriatic acid (normally

available from pool stores) with water in a ratio of four parts water to one

part acid.

CAUTION: FOLLOW THE DIRECTIONS FOR USE AS STATED ON THE 

SUPPLIERS BOTTLE AND ALWAYS PROTECT YOUR EYES,

WEAR RUBBER GLOVES AND AVOID BREATHING FUMES.

15 - If lime or hard water calcium deposits are encountered, lime removal

products that are available for household cleaning may be used.

CAUTION: NEVER USE ABRASIVE PRODUCTS TO REMOVE DEPOSITS AS

THEY WILL DAMAGE THE SURFACE OF THE THIMBLE AND

DECREASE THE UV TRANSMISSION CHARACTERISTICS OF

THE HIGH QUALITY QUARTZ FROM WHICH THE THIMBLE IS

MANUFACTURED.

16 - After cleaning the outer surface, ensure that the thimble is completely dry

both externally and internally and also visually inspect the thimble for any 

signs of cracking that could lead to premature failure while in operation.

17 - Re-insert the glass thimble into the reactor housing. The bottom end of the

thimble has to be located into a recess in the bottom cap. The thimble will

not go all the way down if it is not located into the recess.

18 - Place the black rubber sealing ring all the way inside the black plastic

sealing nut with the angled edge of the sealing ring facing downwards when

the nut is installed on the sealing gland.

CAUTION: DO NOT ATTEMPT TO FIT THE SEAL ONTO THE THIMBLE AS

THIS WILL NOT EFFECT A PROPER SEAL.

19 - Screw the plastic sealing nut onto the sealing gland taking care not to cross

thread the parts. Tighten gently with a suitable tool taking care not to over-

tighten.

CAUTION: OVER TIGHTENING WILL CRACK THE PLASTIC SEALING NUT

AND WATER LEAKAGE WILL THEN OCCUR.

Summary of Contents for TES18

Page 1: ...UV SYSTEMS FOR RESIDENTIAL SPAS SWIMMING POOLS INSTALLATION OPERATING INSTRUCTIONS TEL NO 44 0 141 810 4861 FAX NO 44 0 141810 5561 E MAIL info triogen com TRIOGEN LTD TRIOGEN HOUSE CRAIGTON GLASGOW...

Page 2: ...e fluctuations in bather loading temperature changes sunshine which dissipates chlorine etc are not taken into consideration So how does one ensure the health of those using the pool without having sp...

Page 3: ...ials When you add chlorine to a pool extreme care must be taken not to overdose the pool water and cause harm to the bathers UV has the advantage over Chlorine in that UV does not add any chemical to...

Page 4: ...on SIZING SELECTION OF THE EQUIPMENT The correct selection of the unit is imperative if the water is to be correctly treated with a UV dose of 30mj cm2 which is the required does rate for effective di...

Page 5: ...has to be fitted in the pool filtration pipework system and should be located after filtration as shown in the diagram below It is recommended that isolating valves are fitted within the inlet and out...

Page 6: ...gaskets onto the face of the union tailpieces and then secure in position by threading the half union nut on the TES unit onto the tailpiece NOTE DO NOT OVERTIGHTEN THE UNION NUT HAND TIGHTENING SHOU...

Page 7: ...SSING OF THE CONNECTIONS 8 The PVC pipework used for the installation should be glued into the union tailpieces using suitable PVC primer and cement as recommended by the pipework supplier 9 The conne...

Page 8: ...TES UV 25 80W 0 58A The plug or fused spur should be fitted with a 3A fuse The circuit for the socket fused spur must be protected by an earth leakage device such as an RCD or ELCB unless a plug is us...

Page 9: ...the maximum pressure rating of 40 psi is not being exceeded 6 Check that the mains power supply to the unit is switched off and then remove the top cap of the unit to allow inspection of the UV react...

Page 10: ...till exists release the top union nut which will allow a little water to escape and the pressure should drop to ZERO Remember to re tighten the nut 6 Remove the top electrical cover Depending on the t...

Page 11: ...ECREASE THE UV TRANSMISSION CHARACTERISTICS OF THE HIGH QUALITY QUARTZ FROM WHICH THE THIMBLE IS MANUFACTURED 16 After cleaning the outer surface ensure that the thimble is completely dry both externa...

Page 12: ...e care not to touch the glass surface with bear hands 25 Slide the lamp into the glass thimble taking care that the top two o rings remain on the lamp ceramic end and go into the glass thimble These o...

Page 13: ...lamp plug and lamp end socket are visible 7 Hold the lamp only by the lamp end piece not the glass and remove the lamp connection plug 8 It is now possible to fully remove the UV lamp 9 Fit the lamp...

Page 14: ...8 TES25 TES18 TES25 TES18 TES25 TES18 25 TES18 25 TES18 25 TES18 25 TES18 25 TES18 25 TES18 25 TES18 25 TES18 25 UV LAMP UV LAMP UV LAMP THIMBLE UV LAMP THIMBLE UV LAMP BALLAST UV LAMP BALLAST THIMBLE...

Page 15: ...tion Triogen is satisfied that the claimed defects are traceable to the original parts or workmanship The warranty will be deemed void if the equipment is serviced by other than a trained service engi...

Reviews: