Triogen TES18 Installation & Operating Instructions Manual Download Page 10

9

MAINTENANCE

The TES UV unit requires very little maintenance during the year, the required 

maintenance is as follows:

UV LAMP THIMBLE CLEANING.

The UV lamp thimble which protects the lamp from direct contact with the pool 

water must be kept as clean and free from external deposits as possible as 

heavy contamination will effect the UV transmission through the quartz glass 

into the water.

It is recommended that the quartz thimble is inspected at least every six 

months.

To remove the UV lamp thimble, the following procedure should be adopted:

1 - Isolate the main power supply to the TES unit.

2 - Switch off the main pool recirculation pump.

3 - Close both the inlet and outlet isolating valves.

4 - Check that the pressure gauge reading has went to ZERO.

5 - If after a few minutes pressure still exists, release the top union nut which

will allow a little water to escape and the pressure should drop to ZERO.

Remember to re-tighten the nut.

6 - Remove the top electrical cover.

Depending on the time taken to reach this stage, the UV lamp may still be hot 

and therefore the system should be left to cool down for at least ten minutes.

7 - Remove the UV bulb by pulling the lamp wire in an upwards direction until

the lamp plug and lamp end socket are visible.

8 - Hold the lamp only by the lamp end piece (not the glass) and remove the

lamp connection plug.

9 - It is now possible to fully remove the UV lamp taking care not to touch the

glass surface of the lamp as this could shorten the lamp-life if contaminated.

Always use clean cotton gloves or a cloth if handling the glass surfaces of

the lamp.

10 - Carefully store the lamp in a clean dry area while proceeding to the next

step.

11 - Remove the back plastic nut using a suitable tool that does not mark or

de-face the plastic material.

Summary of Contents for TES18

Page 1: ...UV SYSTEMS FOR RESIDENTIAL SPAS SWIMMING POOLS INSTALLATION OPERATING INSTRUCTIONS TEL NO 44 0 141 810 4861 FAX NO 44 0 141810 5561 E MAIL info triogen com TRIOGEN LTD TRIOGEN HOUSE CRAIGTON GLASGOW...

Page 2: ...e fluctuations in bather loading temperature changes sunshine which dissipates chlorine etc are not taken into consideration So how does one ensure the health of those using the pool without having sp...

Page 3: ...ials When you add chlorine to a pool extreme care must be taken not to overdose the pool water and cause harm to the bathers UV has the advantage over Chlorine in that UV does not add any chemical to...

Page 4: ...on SIZING SELECTION OF THE EQUIPMENT The correct selection of the unit is imperative if the water is to be correctly treated with a UV dose of 30mj cm2 which is the required does rate for effective di...

Page 5: ...has to be fitted in the pool filtration pipework system and should be located after filtration as shown in the diagram below It is recommended that isolating valves are fitted within the inlet and out...

Page 6: ...gaskets onto the face of the union tailpieces and then secure in position by threading the half union nut on the TES unit onto the tailpiece NOTE DO NOT OVERTIGHTEN THE UNION NUT HAND TIGHTENING SHOU...

Page 7: ...SSING OF THE CONNECTIONS 8 The PVC pipework used for the installation should be glued into the union tailpieces using suitable PVC primer and cement as recommended by the pipework supplier 9 The conne...

Page 8: ...TES UV 25 80W 0 58A The plug or fused spur should be fitted with a 3A fuse The circuit for the socket fused spur must be protected by an earth leakage device such as an RCD or ELCB unless a plug is us...

Page 9: ...the maximum pressure rating of 40 psi is not being exceeded 6 Check that the mains power supply to the unit is switched off and then remove the top cap of the unit to allow inspection of the UV react...

Page 10: ...till exists release the top union nut which will allow a little water to escape and the pressure should drop to ZERO Remember to re tighten the nut 6 Remove the top electrical cover Depending on the t...

Page 11: ...ECREASE THE UV TRANSMISSION CHARACTERISTICS OF THE HIGH QUALITY QUARTZ FROM WHICH THE THIMBLE IS MANUFACTURED 16 After cleaning the outer surface ensure that the thimble is completely dry both externa...

Page 12: ...e care not to touch the glass surface with bear hands 25 Slide the lamp into the glass thimble taking care that the top two o rings remain on the lamp ceramic end and go into the glass thimble These o...

Page 13: ...lamp plug and lamp end socket are visible 7 Hold the lamp only by the lamp end piece not the glass and remove the lamp connection plug 8 It is now possible to fully remove the UV lamp 9 Fit the lamp...

Page 14: ...8 TES25 TES18 TES25 TES18 TES25 TES18 25 TES18 25 TES18 25 TES18 25 TES18 25 TES18 25 TES18 25 TES18 25 TES18 25 UV LAMP UV LAMP UV LAMP THIMBLE UV LAMP THIMBLE UV LAMP BALLAST UV LAMP BALLAST THIMBLE...

Page 15: ...tion Triogen is satisfied that the claimed defects are traceable to the original parts or workmanship The warranty will be deemed void if the equipment is serviced by other than a trained service engi...

Reviews: