SAFETY GUIDELINES
The system designer should be aware that devices in Controller systems could fail and thereby create an
unsafe condition. Furthermore, electrical interference in an operator interface, such as an
UNIPLAY
, can
lead to equipment start-up, which could result in property damage and/or physical injury to the equipment
operator.
COMMUNICATIONS CONNECTIONS
The communication ports are located on the underside of the
UNIPLAY
. COM1, COM2, USB host, USB client
and SD card ports are not used.
Ethernet:
A 1:1 or cross-over Ethernet cable may be used to connect the
UNIPLAY
screen to a
Motion Coordinator
or
Ethernet switch.
Speaker:
An external speaker / buzzer may be used for greater keypress feedback. Connection is via a 3.5mm mono
jack plug.
DIP switch settings:
SW1
SW2
SW3
SW4
Mode
ON
OFF
OFF
ON
Touch Screen Calibrate mode
OFF
ON
OFF
ON
Hide HMI System Setting Bar
OFF
OFF
ON
ON
Boot Loader mode
OFF
OFF
OFF
ON
Normal
OFF
OFF
OFF
OFF
Not Supported
SW4 is used for adjusting LCD parameters, please keep it in the manufacturer default position,
otherwise incorrect screen display may be occurred.
SOFTWARE INSTALLATION
No software installation is required to use the
UNIPLAY
Industrial HMI system. Installation of any
additional software on the device by users will invalidate the warranty.
ON
1 2 3 4