Page 1: ...User s Guide TS 700 SS Digital Indicator Series 3 Version 3 0 11 15 10 Triner Scale Mfg Co Inc 800 238 0152...

Page 2: ...unless done so by a qualified scale technician WARNING The indicator is the static and sensitive equipment cut off the power during electrical connections internal components touched by hand is prohi...

Page 3: ...____ 3 Serial Port Connections __________________________ 4 Operation ______________________________________ 5 Parameters and Settings _________________________ 7 Data Output Formats _________________...

Page 4: ...100 250V Operation temperature 10 C 40 C Operation humidity 90 RH Storage temperature 40 C 70 C Battery Operation Before operating with the internal battery charge the battery fully for 18 hours The b...

Page 5: ...oad cells 4 wire or 6 wire configurations Excitation voltage for the load cell is 5VDC the largest output current 120mA Terminal Block on Circuit Board Circuit Board Terminals Load cell EXC voltage SI...

Page 6: ...4 Serial Port Connection RS232 Terminal on Circuit Board DB9 Definition Function 2 TXD Sending data 3 RXD Receiving data 5 GND Ground interface Note if RS485 The connection pin is 2 and 5 pin...

Page 7: ...Scale With weight on scale press key to hold weight To Hold Peak Weight of Multiple Weighings Without weight on scale press key to put indicator in peak hold mode To Remove Hold Function Press key aga...

Page 8: ...If you wish to clear the totals memory press the Zerro Up Arrow key to change the Clr n display to Clr y Press the Print key to accept the Clear Yes prompt kg lb Change pounds kilograms Gross For use...

Page 9: ...You can move forward through all parameters and view the settings by pressing the PRINT ENTER key repeatedly Navigate to the setting parameter you wish to adjust and use the arrow keys to change the s...

Page 10: ...within 60 minutes Power saving setting C10 Options 0 close power saving setting 3 close display if no change within 3min 5 close display if no change within 5 min Hold function C11 Options 0 no hold f...

Page 11: ...lay 2 Print method connect printer 3 Command request method connect computer 4 PC continues sending format connect computer 5 PC big display continuous sending format Communication setting C19 Baud ra...

Page 12: ...manual zero range Zero tracking CAUTION Changing these parameters will effect the indicator s performance C23 Automatically zero tracking time Options 0 disable zero tracking time 1 1 second 2 2 secon...

Page 13: ...ons 0 close dynamic filter 1 1 digital filter strength 2 2 digital filter strength 3 3 digital filter strength 4 4 digital filter strength 5 5 digital filter strength 6 6 digital filter strength CAUTI...

Page 14: ...34 Communication add C34 0 99 Add Code RESERVED Wireless communication C35 C35 0 99 signal RESERVED Gravity of calibration location C36 CAUTION Changing these parameters will effect the indicator s pe...

Page 15: ...6 State A Bits0 1 2 0 1 2 Decimal point position 1 0 0 XXXXXX0 0 1 0 XXXXXXX 1 1 0 XXXXX X 0 0 1 XXXX XX 1 0 1 XXX XXX Bits3 4 Division 0 1 X1 1 0 X2 State B BitsS function Bits0 gross 0 net 1 Bits1 S...

Page 16: ...mode NT net mode S3 weight of positive and negative or S4 kg or lb Data weight value including decimal point CR carriage return LF line feed Serial Interface Reception Command RS232COM serial interfac...

Page 17: ...eceive data format 5 4 Print format ID NO 004 Serial No Date XX XX XX yy mm dd Time XX XX XX hh mm ss GROSS 8 88kg gross weight TARE 2 88kg tare NET 6 00kg net weight 5 5 PC or Big display continuous...

Page 18: ......

Page 19: ...cking load cell check input and output resistance to judge it is good or not ERR1 During calibration not input the weights or the weight is overload Input the correct weights ERR2 During calibration t...

Page 20: ...pacity calibration 0 C07 Restore default 0 C08 Warning tone 1 C09 Power off automatically 0 C10 Power saving mode 0 C11 Hold function 0 C12 Prohibit kg lb conversion C13 Upper limit alarm 000000 C14 U...

Page 21: ...1 C27 Standstill range 2 C28 Dynamic filter 0 C29 Noisy filter 2 C30 Print format 0 C31 Analog signal options 1 C32 4 20mA testing 4 C33 Relay output setting 1 C34 Muti PC communication add 0 C35 Wire...