Door Handing Determination
The position of the Electric Strike in the door
jamb will be the same for a right-handed door
and a lefthanded door. For these installations,
the Electric Strike position in the door jamb
will be as shown in Figure 3.
In a similar manner, the position of the Electric
Strike in the door jamb will be the same for a
lefthanded reverse bevel door and a right
-handed door. For these installations, the
Electric Strike position in the door jamb will be
as shown in figure (4).
NOTE
The EN Electric Strike must be installed with
coil assembly up (wiring toward top of unit). In
this position, the Electric Strike will be locked
without power, Fail Secure, or locked with
power, Fail Safe action. Before performing
Handing Procedure, view Electric Strike in up
position (wire leads at top) to determine if a
handing change is required.
Figure 3.
Position of
Electric Strike
for Right Hand
Inswinging and
Left Hand
Outswinging
Door
Figure 4.
Position of
Electric Strike
for
Left Hand
Inswinging and
Right Hand
Outswinging
Door
Wire
Latch
400RP
400RP
400
400
Figure 10a. USING DC TRANSFORMER
SAMPLE WIRING DIAGRAMS
FOR THE EN SERiES
Figure 10b. USING AC TRANSFORMER
24V DC OR 12V DC
TRANSFORMER
TO 120V AC LINE
PUSH
BUTTON
NORMALLY OPEN
** When wiring the optional buzzer, polarity must be
observed. Connect the (+ or RED) positive wire to the
(+) positive side of the circuit and the (- or BLACK)
negative side wire terminal to the negative side of the
circuit.
+
-
+
RED
-
BLACK
FAIL-SECURE
ELECTRIC
STRIKE
OPTIONAL**
BUZZER: BZ-12 OR BZ-24
OPTIONAL** BUZZER: BZ-12 OR BZ-24 BZ-6 FOR LC VERSION
FAIL-SAFE
ELECTRIC
STRIKE
RECTIFIER*
24V AC or 12V AC Transformer
TO 120V AC LINE
PUSH
BUTTON
NORMALLY OPEN
* The rectifier can be positioned before of after the push button in the circuit. The LC
module can ONLY be positioned after the push button as shown above.
*** When wiring the optional buzzer,
polarity must be observed
. Connect the (+ or
RED) positive wire to the (+) positive side of the circuit and the (- or BLACK) negative
side wire terminal to the negative side of the circuit.
+
-
+
RED
-
BLACK
INSTALLATION PROCEDURE:
- For new or replacement installation in wood
or metal jambs.
1. Verify that voltage rating of Electric Strike is
compatible with supply voltages of installtion.
Coil voltages are color coded.
WIRE LEAD
CODE/STRIPE
12AC
Blue/Orange Stripe
12DC
2 Orange Stripe
24AC
Blue/Black Stripe
24DC
2 Black Stripe
2. Using template supplied with Electric Strike,
mark door jamb for cutout and screw holes.
NOTE
For proper installation, center line of latches must
be aligned with center line of Electric Strike.
3. Prepare door frame (cut out jamb if
required) for Electric Strike. Leave sufficient
space for splicing between power supply
wiring and Electric Strike wiring.
4. If required, run new wiring to door frame
mounting hole. See figure 10 for typical wiring
installations. Refer to wiring chart below for
correct wire size. (Total wiring length includes
routing to door-release push button).
Total Wiring Length
To Transformer 12V
24V
Up to 50 Ft
18AWG 20AWG
50 to 150 ft
16AWG 18AWG
150 to 300 ft 14AWG 16AWG
300 to 600 ft 12AWG 14AWG
NOTE
For DC operation, to obtain an audible
signal when Electric Strike is energized,
install buzzer type BZ-12 for 12VDC
operation, or BZ-24 for 24VDC operation
(purchased seperately), as illustrated in
figure 10. 5. Hold Electric Strike upright
(wiring toward top) and determine if
handing is required. If so, perform handing
procedure.
6. Splice Electric Strike wiring to supply
wiring. Secure with wire nuts (supplied).
7. For wood and aluminum door jambs, drill
pilot holes for securing Electric Strike to
door jamb. For steel and aluminum door
jambs, secure Electric Stike to existing
mounting tabs.
8. Install Electric Strike into door jamb and
secure with flat head mounting screws
(supplied).
9. Verify that door operates correctly when
Electric Strike is energized and not
energized.
NOTE
1. Rectifier can be located either between
transformer and push button, or between
push button and electric strike.
2. Use either a silicon rectifier or a current
regulating rectifier for converting the AC
voltage at the transformer secondary to
the DC for operating the electric strike.