TMCM-1076 Hardware Manual • Hardware Version V1.10 | Document Revision V1.00 • 2018-JUN-25
11 / 22
5 Functional Description
5.1 Typical Application Wiring
Wire the TMCM-1076 as shown in the following figures.
• Connect the the power supply to V+ and GND.
• Connect the Step and Direction signals to your motion controller.
• At power up time, the EN input must be low (= driver stage disabled)!
• Optional: Connect UART to a TTL UART interface with 5V logic levels. To configure your TMCM-1076
connect start the TMCL-IDE and use the parameterization tools. For detailed instructions refer to the
TMCM-1076-firmware-manual.
Note
The TTL UART interface is not optically isolated. It has and requires 5V level
signals.
Nevertheless, it provides basic ESD and rail-to-rail signal line protection for the
TMCM-1076.
+5V
+5V
TMCM-1076 /
PD-x-1076
GND
EN
DIR
STEP
CHOP
User
MCU
A1
B2
A2
B1
M
COMM
270
Ω
270
Ω
270
Ω
270
Ω
RXD
TXD
Driver &
Controller
9V-28V
V+
GND
Figure 7: Typical application scenario with 5V inputs
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at
www.trinamic.com