16 / 60
17 / 60
10173312 / XI 18
/ ©trilux.com
10173312 / XI 18
/ ©trilux.com
BICULT
OVERVIEW OF NETWORKING
BICULT
NETWORKING
Type
Bicult Act ... SMC ...
(SMART Connect)
≈ kg
4,1
E
E
www.trilux.com/bicult-app
SMART Connect
Initial PIN: 201812
PIN*
INFORMATION
•
Bicult Smart Connect
can be grouped together. The maximum group size is 20 luminaires.
• For all luminaires in a group, the HCL curves of the indirect light components are synchronised
to create a uniformly illuminated ceiling appearance.
• The direct light component always remains in the control of the user and cannot be controlled
via the group.
• If a luminaire in the group detects presence in the room, all luminaires in the group switch
on the indirect light component. The direct light component only switches on as soon as the
individual luminaires detect presence.
• The group is set up and processed via the
Bicult Smart Connect
menu within the Bicult app.
App menu item:
»Settings > Smart Connect«
• The
Bicult Smart Connect
menu is password-protected. The initial PIN is: 201812.
• The HCL curve is the same for all luminaires in the group. All other settings of the master
luminaire can also be adopted for the other luminaires in the group.
• Each
Bicult Smart Connect
is equipped with sensor technology. The sensor technology
continues to operate independently in each luminaire, even if it is networked in a group.
• With networked luminaires, settings can only be made via the
Bicult Smart Connect
menu.
individual
individual
synchronous
synchronous
individual
• No person present - all luminaires are switched off.
• A person enters the room - a luminaire detects the presence. All
luminaires switch on the indirect light component. General lighting
in the room is ensured.
• The person goes to their workplace - the direct light component of
the luminaire at the workstation switches on. Only the indirect light
component is switched on at unoccupied workstations.
• All persons leave the room - all luminaires switch off after the delay
time.
*Initial PIN: 201812