Trilux 7093759 Operating Instructions Manual Download Page 6

For your own safety, read all notices and operating steps carefully. Keep the instructions for 

future reference.

SAFETY NOTES

E

BICULT

BICULT

E

HUMAN CENTRIC LIGHTING

The light source (LED module) of this luminaire cannot be replaced.

• If the light source malfunctions or fails, please contact TRILUX.

• When the light source has reached the end of its service life, replace the entire 

luminaire.

Prevention of cable breakage

•  Disconnect the connection cable from the socket only by pulling the mains 

plug.

Important information on the connecting cable 

(X)

• Operate the luminaire only with an undamaged outer flexible cable. If the outer flexible 

cable is damaged, it must be replaced by a special cable or by a cable available exclusively 

from TRILUX or its service partner.

HUMAN CENTRIC LIGHTING  (HCL) WITH BICULT

Current scientific findings demonstrate that all forms of lighting (artificial and natural), in addition 
to their visual impact, also have a biological effect on people. Only the correct and responsible use 
allows for optimal exploitation of these benefits and avoids risks. 

The reference for TRILUX is always natural daylight with its colour temperature, dynamism and 
intensity. We only need to illuminate with artificial light if there is no natural daylight or if daylight 
supply is insufficient. 

Bicult LED

 with its automatic circadian light becomes an efficient, customised system that can 

perfectly support people in their various tasks. TRILUX Human Centric Lighting solutions focus on 
people and their needs and promote well-being, productivity and relaxation – for healthy work in 
offices.

10 / 60

   10173312 / XI 18

 

/ ©trilux.com

 10173312 / XI 18

 

/ ©trilux.com

11 / 60

INTENDED USE

• Intended for indoor rooms with an ambient temperature of: 

ta 25 °C

• 

Bicult ... EU: suitable for operation with the control gear box Bicult Act T ... ETDI ... 

EU (TK No. 10174469)

• 

Bicult ... UK: suitable for operation with the control gear box Bicult Act T ... ETDI ... 

UK (TK No. 10174470)

• LED module: 

risk group 1

• Protection rating: 

IP20

• Safety class: 

II

Disposal of waste electrical and electronic equipment

• Always collect and dispose of old electrical and electronic equipment separa-

tely at the end of its service life. In case of doubt, seek information about 

environmentally-compliant waste disposal from your local district authority 

or special waste disposal companies. 

Simplified EU Declaration of Conformity

• TRILUX hereby declares that the radio system type in the following luminaire types 

complies with Directive 2014/53/EU: 

Bicult SMS ... , Bicult SMC ...

  The full text of the EU Declaration of Conformity is available on the internet:

 

www.trilux.com/eu-conformity

04:00

08:00

12:00

16:00

20:00

Colour temperature [K]

2700 - 6500

HCL curve

HCL curve

Sensors

Networking

automatic

-

automatic/settable via app

Light sensor/
movement sensor

Light sensor/
movement sensor

-

-

yes, up to 
max. 20 luminaires

automatic/settable via app

Bicult Act

COMFORT (COM)

Bicult Act

SMART Single (SMS)

Bicult Act

SMART Connect (SMC)

TYPE OVERVIEW

Summary of Contents for 7093759

Page 1: ...CONNECT TRILUX GmbH Co KG Heidestra e D 59759 Arnsberg 49 2932 301 0 info trilux de www trilux com D BEDIENUNGSANLEITUNG E OPERATING INSTRUCTIONS F INSTRUCTIONS D UTILISATION I ISTRUZIONI PER L USO S...

Page 2: ...icht zu einem leistungsf higen ma geschnei derten System das den Menschen optimal bei seinen verschiedenen Aufgaben unterst tzen kann Human Centric Lighting L sungen von TRILUX stellen den Menschen un...

Page 3: ...manuelle Verstellung der Farbtemperatur Taster leuchtet nicht Einstellungen erfolgen f r das direkte und indirekte Licht synchron Einstellung direkter Lichtaustritt Durch Drehen des Leuchtenringes ka...

Page 4: ...cult app Type Bicult Act T SMS SMART Single Bicult Act T SMC SMART Connect kg 4 1 4 1 Lichtsensor HF Bewegungsmelder 1 6 m 1 m 1 2 Erfassungsbereich einstellbar per App Ausrichtung durch Drehen des Le...

Page 5: ...App App Men punkt Einstellungen Smart Connect Das Bicult Smart Connect Men ist passwortgesch tzt Der Initial PIN lautet 201812 Die HCL Kurve ist f r alle Leuchten in der Gruppe gleich Alle weiteren E...

Page 6: ...system that can perfectly support people in their various tasks TRILUX Human Centric Lighting solutions focus on people and their needs and promote well being productivity and relaxation for healthy...

Page 7: ...available to charge devices such as smartphones tablets and other USB chargeable units Push button for light colour short press circadian light ON button lights up OFF long press manual adjustment of...

Page 8: ...rilux com bicult app Type Bicult Act T SMS SMART Single Bicult Act T SMC SMART Connect kg 4 1 4 1 Light sensor HF motion detector 1 6 m 1 m 1 2 Detection range settable via app Alignment by rotating t...

Page 9: ...ult app App menu item Settings Smart Connect The Bicult Smart Connect menu is password protected The initial PIN is 201812 The HCL curve is the same for all luminaires in the group All other settings...

Page 10: ...ir de mani re optimale ses utilisateurs dans l accomplissement de leurs diverses t ches Les solutions de HUMAN CENTRIC LIGHTING de TRILUX placent l Homme et ses besoins au premier plan en favorisant l...

Page 11: ...re de couleur Appui bref clairage circadien ALLUM le BP s allume TEINT Appui long R glage manuel de la temp rature de couleur le BP ne s allume pas Les r glages de la lumi re directe et indirecte s ef...

Page 12: ...t T SMS SMART Single Bicult Act T SMC SMART Connect kg 4 1 4 1 Capteur de lumi re Capteur de mouvement HF 1 6 m 1 m 1 2 Plage de d tection r glable via application Orientation en tournant la bague de...

Page 13: ...l application Bicult R glages Smart Connect Le menu Bicult Smart Connect est prot g par mot de passe Le num ro du code NIP initial est 201812 La courbe HCL est la m me pour tous les luminaires du grou...

Page 14: ...odo ottimale l individuo nell esercizio delle sue diverse attivit Le soluzioni di Human Centric Lighting proposte da TRILUX sono focalizzate sull essere umano e le sue esigenze migliorando sensazione...

Page 15: ...Pulsante per colore della luce Premere brevemente Luce circadiana attiva pulsante si accende disattiva Premere a lungo Regolazione manuale della temperatura di colore pulsante non si accende Settings...

Page 16: ...bicult app Type Bicult Act T SMS SMART Single Bicult Act T SMC SMART Connect kg 4 1 4 1 Sensori ottico Rilevatire di movimento HF 1 6 m 1 m 1 2 Campo di rilevazione impostabile via app Posizionamento...

Page 17: ...stazioni Smart Connect Il menu t protetto da password Il PIN iniziale 201812 La curva HCL uguale per tutti gli apparecchi del gruppo Anche tutte le altre impostazioni dell apparecchio master possono e...

Page 18: ...oyar a las personas de forma ptima en sus diferentes tareas Las soluciones de Human Centric Lighting de TRILUX ponen en el centro a las personas y a sus necesidades y fomentan el bienestar la producti...

Page 19: ...ar a trav s del USB Pulsador color de la luz Pulsaci n breve ENCENDER la luz circadiana el pulsador est iluminado APAGAR Pulsaci n larga Ajuste manual de la temperatura de color el pulsador no est ilu...

Page 20: ...T SMS SMART Single Bicult Act T SMC SMART Connect kg 4 1 4 1 Sensores de Luz Detector de movimiento de alta frecuencia 1 6 m 1 m 1 2 rea de detecci n ajustable a trav s de la aplicaci n Orientaci n a...

Page 21: ...nect El men Bicult Smart Connect est protegido por contrase a El PIN inicial es 201812 La curva HCL es la misma para todas las luminarias del grupo Todos los dem s ajustes de la luminaria master tambi...

Page 22: ...at gemaakt systeem dat de mens optimaal kan ondersteunen bij al zijn taken Human Centric Lighting systemen van TRILUX plaatsen de mens met zijn behoeften centraal en bevorderen welzijn productiviteit...

Page 23: ...es tablets en andere via USB oplaadbare apparaten te laden Toets lichtkleur kort indrukken circadiaans licht AAN toets brandt UIT long press manual adjustment of colour temperature button does not lig...

Page 24: ...ilux com bicult app Type Bicult Act T SMS SMART Single Bicult Act T SMC SMART Connect kg 4 1 4 1 Lichtsensor HF bewgingsmelder 1 6 m 1 m 1 2 Detectiebereik instelbaar via app Richtbaar door te draaien...

Page 25: ...app Menupunt in de app Instellingen Smart Connect Het Bicult Smart Connect menu is beveiligd met een wachtwoord De initi le PIN is 201812 De HCL curve is gelijk voor alle armaturen in de groep Ook all...

Page 26: ...rzy wykonywaniu r nych zada Rozwi zania Human Centric Lighting firmy TRILUX koncentruj si na cz owieku i jego potrzebach wspieraj c dobre samopoczucie produktywno i relaks a tym samym zdrowe warunki p...

Page 27: ...ie naci ni cie przycisku wiat a w rytmie dobowym ON przycisk wieci OFF D ugie naci ni cie przycisku regulacja temperatury barwowej przycisk nie wieci Regulacja wiat a bezpo redniego i po redniego odby...

Page 28: ...Bicult Act T SMS SMART Single Bicult Act T SMC SMART Connect kg 4 1 4 1 Czujnik wiat a Czujnik ruchu HF 1 6 m 1 m 1 2 obszar detekcji ustawiany w aplikacji kierunek ustawiany przez obracanie pier cien...

Page 29: ...t menu aplikacji Ustawienia Smart Connect Menu Bicult Smart Connect jest chronione has em PIN pocz tkowy brzmi 201812 Krzywa HCL jest taka sama dla wszystkich opraw w grupie Wszystkie inne ustawienia...

Page 30: ...d utilisation pour le d montage ou pour les travaux de maintenance ult rieurs Vous avez la possibilit de consulter des informations importantes concernant l efficacit nerg tique des luminaires TRILUX...

Page 31: ...TRILUX GmbH Co KG Heidestra e D 59759 Arnsberg 49 2932 301 0 info trilux de www trilux com...

Reviews: