Grounding and Protecting the Device
The surge protector box should be attached to the
bottom of the Extender Bridge. The surge protector will
be attached using the ground screw as a pivot point
then the box will be swung into place against a mounting
bracket screw.
Remove the ground screw from the base of the
device, and then loosen (but do not remove) the
screw on the same side of the bracket as the
ground screw
Run the ground screw through the lug of the green
ground wire coming from the surge protector and
the hole in the surge protector bracket.
Before tightening the ground screw, remove a
section of the insulation on the ground wire which
will attach to the ground point on the mounting
structure and wrap this section around the ground
screw.
Pivot the box into place such that the other end of
the surge protector’s mounting bracket touches the
loosened screw. Tighten both screws.
Be sure to connect the ground wire to the
grounding point on the mounting structure.
Run the CAT5e cable under the gasket and plug it
into the Ethernet port in the cavity on the device
base (see the diagram to the right)
.
CAT5e
Ethernet Cable
8P8C Ethernet
Port
8P8C serial
port
View of underside with cover plate removed
ground wire
ground wire to
mounting
structure
ground screw