Notice: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc., its susidiaries, affiliates, and/or
licensors. This document is provided subject to the confidentiality obligations set forth in the agreement between your company and Trilliant. The contents
may not be used or disclosed without the express written consent of Trilliant.
47
Installation Guide for SecureMesh® CONN-2000 - PL-0689A
Figure 19:
The Plug's Grounding Clip
5. Ensure the pairs of the conductors are ordered as they should be. Then slide
them onto the conductor spacer.
Figure 20:
The Pairs of the Conductors on the Conductor Spacer
6. Trim the conductors so that the tips are exposed to the jacket at 0.6 in.
7. Twist and fold back the braid and drain the wires.
8. Align the wires to insert them into the plug housing.