IV.

 

Technical parameters 

Number of IP communicators 

Unlimited 

Number of reception channels 

Initial license allows two channels 

Communication protocols 

TCP/UPD TRK-3, TRK-6, TRK-7 

Physical port of network adapter card 

RJ-45 (FastEthernet 10/100) 

Modem of integrated SMS receiver 

GSM 850/ 900/ 1800/ 1900 MHz 

Integrated SMS receiver SIM card type 

Standard, not supplied with the receiver 

Purpose of RS232 ports 

It can configured to work as INPUT or OUTPUT for data 
transferring 

Number of RS232 ports 

Data output protocols 

Surgard MLR2-DG, Monas3 

Physical type of RS232 ports 

Male connector DB9 

Setting parameters and monitoring the 
operation 
 

Computer operating in the same network with MS 
Windows 32/64 bit Win7, Win8, Win8.1, Win10 and 
software IPcomControl v4 

Number of workplaces 

Initial license allows adding 2 workplaces 

Primary power supply 

110 – 240 V (50 / 60 Hz) AC network 

Power / Current consumption 

Up to 60W / 0.35A 

Backup power supply 

12 V, capacity of 18Ah or more. Charging current up to 
900 mA. 

Operating  temperature 

From 0 °C to +55 °C 

Dimensions 

19” 2U (450 x 50 x 320 mm) 

Weight 

3.8 kg 

V.

 

Equipment 

 

Multichannel receiver RM14 

1 pc. 

 

2.5 m length GSM antenna with a magnetic pad 

1 pc. 

 

1.5 m length power supply cable 

1 pc. 

 

1.8 m length Null Modem-type COM cable (f/f) 

1 pc. 

 

5 m LAN cable 

1 pc. 

 

CD with software IPcomControl v4 and user manual 

1 pc. 

 
 
 
 
 
 

Summary of Contents for RM14

Page 1: ...Multichannel IP SMS receiver RM14 User Manual UAB TRIKDIS Draugystės g 17 LT 51229 Kaunas Tel 370 37 408040 Fax 370 37 760554 E mail info trikdis lt www trikdis lt ...

Page 2: ...a receiver operating in LAN Error Bookmark not defined C Configuring remote server IP address for communication channel testing receiver sound signals and clock tab Configure Error Bookmark not defined D List of receiver events Disabling generation of event messages tab Events 12 E Controlling communication with GPRS and GSM objects tab General 12 F Setting operation mode of COM ports tab COM sett...

Page 3: ... device therefore it may only be installed by qualified specialists following this manual and regulations for installing electrical equipment Multichannel receiver RM14 must be operated following this manual and regulations for safe operation of electrical equipment ...

Page 4: ...y TRIKDIS Ethernet communicators E10 E10C E10T via wired internet networks Receives messages using TCP IP or UDP IP protocols sent by TRIKDIS GPRS communicators G10F FireCom via GPRS and or SMS channels Receives messages using TCP IP or UDP IP protocols sent by TRIKDIS control panels CG3 and SP131 via GPRS and or SMS channels Receives messages using UDP IP protocols sent by TRIKDIS repeaters RR GS...

Page 5: ...hysical type of RS232 ports Male connector DB9 Setting parameters and monitoring the operation Computer operating in the same network with MS Windows 32 64 bit Win7 Win8 Win8 1 Win10 and software IPcomControl v4 Number of workplaces Initial license allows adding 2 workplaces Primary power supply 110 240 V 50 60 Hz AC network Power Current consumption Up to 60W 0 35A Backup power supply 12 V capaci...

Page 6: ...SMS reception is on Status green light when SMS modem is connected and successfully registered in GSM network Red light when connection with the receiver or GSM network is lost Event blue light when an SMS message is being received COM1 Active blue light when port COM1 is described and active Status green light when RS232 connection with another receiver or messages monitoring software is online R...

Page 7: ...l receive messages sent using TCP IP UDP IP connection and or SMS messages without inserted receiving adapter cards 1 Power supply must be turned off when receiver is being prepared for operation i e 1 receiver power supply cable must be disconnected from the network and 2 receiver connector BAT to which backup power supply circuit is connected must be unplugged Note Receiver will fully shut down ...

Page 8: ...r section Configuring the receiver 3 Add and describe ports through which message traffic is directed to the message monitoring software see tab Outputs under section Configuring the receiver 4 Add and describe ports through which message traffic will be receiver see tabs COM settings and Receivers under section Configuring the receiver 5 Add and describe programmable receivers which will direct p...

Page 9: ...bnet mask 255 255 255 0 Gateway 192 168 100 254 In order to restore default settings refer to chapter IX Resetting default parameters 1 Computer and receiver must operate in the same network in order to configure the receiver Change the network adapter card addresses of the computer that will be used to configure the receiver to match those indicated in the tab 2 Use LAN cable to connect the recei...

Page 10: ...area network whose addresses were just set in its place 9 Restore network adapter card addresses of the computer that was used to configure the receiver Computer may now operate in previously used networks B Connecting to a receiver operating in LAN Receiver operating in LAN is configured using software IPcomControl v4 on a 32 64 bit computer computer with OS MS Windows Win7 8 8 1 10 Several compu...

Page 11: ...m GM15 connection to GSM network receiver event E R 751 Number of software tabs may differ depending on user permissions granted by the receiver administrator Option to test the quality of message reception from GPRS networks and wide area network WAN receiver event E R 732 Testing is activated when box Ping is ticked and IP address of external network server is entered Server must be capable to r...

Page 12: ...st will happen if no signal is received via GPRS įvyks for time T T GPRS PING interval x GPRS Multiplier Tolerance Receiver event R752 GSM connection restored will happen if no signal is received via SMS for time T T SMS PING interval x GSM Multiplier Tolerance Receiver event R762 GPRS connection restored will happen if N signals will be received via GPRS in time T T GPRS PING interval x GPRS Mult...

Page 13: ...raffic received through Input ports to Output if Input is chosen Output RS232 port for directing data to the message monitoring software COM name of DB9 connector USB name of insertable adapter card slot Programmable receivers of the traffic that is received through these ports may be added in tab Receivers Physical port parameters These parameters must match the settings of corresponding ports of...

Page 14: ...number is included in messages transmitted to the message monitoring software Number of receivers that may be added is limited by license Double click on cell Click to add new line to describe message traffic received by an added receiver assign a port Port or COM input line number protocol encryption password and output Output parameters may be set in tab Outputs Note assigned line number will be...

Page 15: ... field Raw data Messages will be sent to the specified IP address without processing when box Started is ticked Messages will be changed according to protocol Contact ID if box Standard messages is ticked Message filtering parameters are set in field Filter settings Click Add filter to open tab Filter settings Specify the rules for message transmission to the message monitoring software Enter the ...

Page 16: ...one bypass specify permission to send control commands to Trikdis control panel installed in a secured object in order to activate or deactivate Zone bypass mode in a specific zone Set PGM status specify permission to switch message transmission module PGM output status remotely Arm Disarm system specify permission to send control commands to Trikdis control panel installed in a secured object in ...

Page 17: ...IPcomControl Equipment failure to receive data via COM port recorded Zone number indicates port ID E330 System peripheral trouble Transmission module ID Number of repeating modules a New module appears on a system having an object ID of already existent module b A new module s unique number is not in the system E350 Connection trouble Transmission module ID 000 a Transmission module is working in ...

Page 18: ...k cable removed from Ethernet connector R733 WAN cable connected 0000 Receiver ID 000 Network cable plugged back into Ethernet connector E751 GSM connection is offline 0000 Receiver ID 000 GSM modem alarmed about lost connection to GSM network by a service message At least one minute passed after system activation R751 GSM connection is online 0000 Receiver ID 000 Connection loss between GSM modem...

Page 19: ... occur XI License activation Parameters of the initial license can be changed upgraded by installing a new license Go to Options Activate product browse and select license file which is in lic format To install new license press the Apply button XII Warranty According to the user manual of the receiver and general regulations for installing electrical equipment the manufacturer provides a 24 month...

Reviews: