4
1.2.
Technical parameters
GSM modem frequencies
850 / 900 / 1800 / 1900 MHz
GSM communication technologies
TCP/IP or UDP/IP via GPRS
Voice channel in DTMF tones
Message transmission protocols
SIA DC-09-2007 or SIA DC-09-2012
SIA DC-05 Contact ID
Encryption protocol
AES128, encryption key length 128 bits (16 symbols)
or not encrypted
Inputs
CLK, DATA communication via security panel data bus
IN1 and IN2, input type NC
Programmable output
OUT1, OC type, commutates voltage of up to 30 V and direct current of
up to 1 A
Memory
up to 60 messages
Parameters setting
via USB port
Power supply
DC 10 V
÷
15 V
Used current
60
÷
100 mA (on standby),
up to 500 mA (while sending data)
Workplace
Air temperature from -10
q
C to +50
q
C,
Relative humidity up to 80 % when +20
q
C
Measures
65 x 79 x 25 mm
1.3.
Equipment
Communicator
G09
1 pc.
Adhesive mounting tape (10 cm)
1 pc.
Note:
GSM operator SIM card and GSM antenna with screwed male-type connector are also necessary in order to ensure
operation of the communicator.
1.4.
Overall view of communicator G09
1.
GSM antenna connector
2.
Indicator
Network
3.
Indicator
Data
4.
Indicator
Power
5.
Terminal block
6.
USB connection for programming
7.