1.2.

 

Technical parameters 

GSM modem frequencies 

850 / 900 / 1800 / 1900 MHz 

GSM communication technologies 

TCP/IP or UDP/IP via GPRS 
Voice channel in DTMF tones 

Message transmission protocols 

SIA DC-09-2007 or SIA DC-09-2012 
SIA DC-05 Contact ID 

Encryption protocol 

AES128, encryption key length 128 bits (16 symbols) 
or not encrypted 

Inputs 

CLK, DATA communication via security panel data bus 
IN1 and IN2, input type NC 

Programmable output 

OUT1, OC type, commutates voltage of up to 30 V and direct current of 
up to 1 A 

Memory 

up to 60 messages 

Parameters setting 

via USB port 

Power supply 

DC 10 V 

÷

 15 V 

Used current 

60 

÷

 100 mA (on standby), 

up to 500 mA (while sending data) 

Workplace 

Air temperature from -10

q

C to +50

q

C,  

Relative humidity up to 80 % when +20

q

Measures 

65 x 79 x 25 mm 

 

 

 
 

1.3.

 

Equipment 

Communicator 

G09

 

1 pc. 

Adhesive mounting tape (10 cm) 

1 pc. 

 

 

Note:  

      GSM operator SIM card and GSM antenna with screwed male-type connector are also necessary in order to ensure 
operation of the communicator. 
 

 
 

1.4.

 

Overall view of communicator G09  

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 

 

1.

 

GSM antenna connector 

2.

 

Indicator 

Network

 

3.

 

Indicator 

Data

 

4.

 

Indicator 

Power 

5.

 

Terminal block 

6.

 

USB connection for programming 

7.

 

SIM card slot 

 

Summary of Contents for G09

Page 1: ...GSM communicator G09 v 1 61 User Manual and Installation Guide Draugystes g 17 LT 51229 Kaunas E mail info trikdis lt www trikdis lt...

Page 2: ...tion parameters 8 4 Upgrading communicator firmware 13 5 Remote device control using SMS messages 13 6 Warranty and limitation of liability 14 7 Annex 1 Communicator messages 15 Safety requirements Be...

Page 3: ...protocols following SIA standard DC 09 requirements Received or generated message is sent via set main channel Communicator sends messages to users once a message reception confirmation is received fr...

Page 4: ...direct current of up to 1 A Memory up to 60 messages Parameters setting via USB port Power supply DC 10 V 15 V Used current 60 100 mA on standby up to 500 mA while sending data Workplace Air temperat...

Page 5: ...ower supply and microprocessor are in operation voltage is regular Yellow flashing Insufficient power supply voltage below 11 5 V microprocessor is in operation Green and yellow flashing in turns Prog...

Page 6: ...nting 4 Screw the GSM antenna 5 Connect communicator to security control panel according to the diagram See section Connection diagrams 6 Turn on the power supply 7 Check light indicators to evaluate...

Page 7: ...28 1738 MAGELLAN MG5000 MG5050 DIGIPLEX EVO48 EVO192 EVO96 NE96 ESPRIT E55 728ULT 738ULT Connecting to Pyronix Matrix Series security control panels MATRIX 424 MATRIX 832 MATRIX 832 MATRIX 6 MATRIX 81...

Page 8: ...ion options will open Click Browse and select the location where USB_COM inf is saved To finish the USB driver installation follow remaining installation wizard commands 2 Run G10config 3 Select Conne...

Page 9: ...ntification number Hex Tick if hexadecimal numbers will be used for entering the object ID SIM card PIN code Field for SIM card PIN code Leave the field empty if PIN code request is disabled User code...

Page 10: ...ckup communication channel Works with security control panel Select the type of the security control panel to which communicator G09 is connected Choose INTERFACE C11 if a connection C11 or C14 will b...

Page 11: ...n is able to control it Untick if not IP addresses port and phone numbers encryption protocol and key other parameters may only be submitted by the station manager APN GSM network operator access poin...

Page 12: ...send communication test messages Test via SMS messages event codes E6XX See Annex 1 SMS encoding Select the desired SMS encoding from the list Object ID Enter the object name which will be included in...

Page 13: ...res 1 Download the newest G09_vx xx prg file from www trikdis lt 2 Connect the communicator G09 to the computer open G10config and select Firmware in the menu 3 Click Browse and select file G09_vx xx...

Page 14: ...burse the resulting property or non pecuniary damages By purchasing the product the Buyer agrees that TRIKDIS sold a Product that satisfies the requirements of the Buyer TRIKDIS does not guarantee tha...

Page 15: ...n control panel E R 302 309 E 302 Low System battery Battery Power failure on control panel R 302 Low system Battery restore Battery Power restored failure on control panel E R 321 E 321 Bell 1 Bell t...

Reviews: