background image

 

 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

GSM communicator 

G09

 

(v.1.61) 

 

User Manual and Installation Guide 

 
 
 
 
 
Draugystes g. 17, 
LT-51229 Kaunas 
E-mail: [email protected] 

www.trikdis.lt

 

 
 

 

Summary of Contents for G09

Page 1: ...GSM communicator G09 v 1 61 User Manual and Installation Guide Draugystes g 17 LT 51229 Kaunas E mail info trikdis lt www trikdis lt...

Page 2: ...tion parameters 8 4 Upgrading communicator firmware 13 5 Remote device control using SMS messages 13 6 Warranty and limitation of liability 14 7 Annex 1 Communicator messages 15 Safety requirements Be...

Page 3: ...protocols following SIA standard DC 09 requirements Received or generated message is sent via set main channel Communicator sends messages to users once a message reception confirmation is received fr...

Page 4: ...direct current of up to 1 A Memory up to 60 messages Parameters setting via USB port Power supply DC 10 V 15 V Used current 60 100 mA on standby up to 500 mA while sending data Workplace Air temperat...

Page 5: ...ower supply and microprocessor are in operation voltage is regular Yellow flashing Insufficient power supply voltage below 11 5 V microprocessor is in operation Green and yellow flashing in turns Prog...

Page 6: ...nting 4 Screw the GSM antenna 5 Connect communicator to security control panel according to the diagram See section Connection diagrams 6 Turn on the power supply 7 Check light indicators to evaluate...

Page 7: ...28 1738 MAGELLAN MG5000 MG5050 DIGIPLEX EVO48 EVO192 EVO96 NE96 ESPRIT E55 728ULT 738ULT Connecting to Pyronix Matrix Series security control panels MATRIX 424 MATRIX 832 MATRIX 832 MATRIX 6 MATRIX 81...

Page 8: ...ion options will open Click Browse and select the location where USB_COM inf is saved To finish the USB driver installation follow remaining installation wizard commands 2 Run G10config 3 Select Conne...

Page 9: ...ntification number Hex Tick if hexadecimal numbers will be used for entering the object ID SIM card PIN code Field for SIM card PIN code Leave the field empty if PIN code request is disabled User code...

Page 10: ...ckup communication channel Works with security control panel Select the type of the security control panel to which communicator G09 is connected Choose INTERFACE C11 if a connection C11 or C14 will b...

Page 11: ...n is able to control it Untick if not IP addresses port and phone numbers encryption protocol and key other parameters may only be submitted by the station manager APN GSM network operator access poin...

Page 12: ...send communication test messages Test via SMS messages event codes E6XX See Annex 1 SMS encoding Select the desired SMS encoding from the list Object ID Enter the object name which will be included in...

Page 13: ...res 1 Download the newest G09_vx xx prg file from www trikdis lt 2 Connect the communicator G09 to the computer open G10config and select Firmware in the menu 3 Click Browse and select file G09_vx xx...

Page 14: ...burse the resulting property or non pecuniary damages By purchasing the product the Buyer agrees that TRIKDIS sold a Product that satisfies the requirements of the Buyer TRIKDIS does not guarantee tha...

Page 15: ...n control panel E R 302 309 E 302 Low System battery Battery Power failure on control panel R 302 Low system Battery restore Battery Power restored failure on control panel E R 321 E 321 Bell 1 Bell t...

Reviews: