Description

 

Communicator E10Tv2 is intended to upgrade intruder alarm panel which have telephone line communicator 
(TLC) for event signaling wired Internet (Ethernet).  

Customers  are  informed  about  security  system  events  in  Protegus  app.  Communicator  transmits  full  event 
information to Alarm Receiving Centre.

 

Features 

1.1

 

Technical Parameters 

Parameter 

Description 

Power supply voltage 

12,6 ± 3 VDC 

Current consumption 

120 mA (stand-by),  
Up to 250 mA (transmitting) 

Ethernet connection 

IEEE802.3, 10 Base-T, RJ45 socket 

Data pack content 

Contact ID format codes 

Memory 

Up to 100 messages 

Input 

1, NC/NO/EOL-2,2 kΩ type 

Operating environment 

From -10 °C to 50 °C, with relative air humidity 80% when +20 °C 

Dimensions 

65 x 79 x 25 mm 

 

 

 

 

 

Connection 

 

Connection to control panels via: 

 

TLC terminal connection 

Communications 

 

Simultaneous 

event 

reporting 

to 

Protegus 

Mobile/Web  application,  allowing  user  to  remotely 
monitor alarm system 

 

Communicator  transfers  all  messages  from  control 
panel in Contact ID codes 

 

Messages  in  TCP/IP  or  UDP/IP  protocol  are  sent  to 
ARC 

 

In  case  of  lost  connection  with  the  main  channel, 
switches automatically to backup channel 

 

Input 

 

1 input, type: NC, NO, EOL = 2.2 kΩ 

Configuration 

 

Quick and easy configuration and firmware updates 

 

Two access levels for setting of operating parameters 

Summary of Contents for E10T

Page 1: ...Ethernet communicator E10Tv2 USER MANUAL UAB TRIKDIS Draugystės str 17 LT 51229 Kaunas LITHUANIA E mail info trikdis lt Webpage www trikdis lt ...

Page 2: ...THE COMMUNICATOR TO THE CONTROL PANEL 9 4 2 OPTIONAL CONNECT SENSORS 9 4 3 CONNECT LAN CABLE 9 4 4 TURN ON POWER SUPPLY 10 4 5 PERFORM SYSTEM TEST 10 TRIKDISCONFIG REMOTE CONTROL 10 MANUAL FIRMWARE UPDATE 11 Safety Requirements The security alarm system should be installed and maintained by qualified personnel Prior to installation please read carefully this manual in order to avoid mistakes that ...

Page 3: ... Data pack content Contact ID format codes Memory Up to 100 messages Input 1 NC NO EOL 2 2 kΩ type Operating environment From 10 C to 50 C with relative air humidity 80 when 20 C Dimensions 65 x 79 x 25 mm Connection Connection to control panels via TLC terminal connection Communications Simultaneous event reporting to Protegus Mobile Web application allowing user to remotely monitor alarm system ...

Page 4: ...MCI Data bus for connecting report transmission device 1 5 Light indication LED Operation Description Network displays the status of connection to the Internet Green ON Module is connected to the Internet Yellow ON TCP IP session is open Data displays data transfer Green ON Unsent messages present Red ON Messages cannot be sent Green flashing Messages are being received from the control panel Powe...

Page 5: ...ommunicator E10Tv2 onfiguration 2 CAT 5 Ethernet cable maximum 100m not included 3 At least 4 wires cable for connecting communicator to control panel 1 8 System view Connecting E10Tv2 to TrikdisConfig Communicator can be configured using TrikdisConfig software via USB cable or remotely The software is available on www trikdis com and operates in MS Windows OS 1 Download and install TrikdisConfig ...

Page 6: ... System settings Settings General Write an appropriate Account number 4 symbols hexadecimal number Select Use security panel account ID checkbox if messages from the security control panel must contain its identification number Test period periodic test messages will be sent according to a time interval set in this section Settings Ethernet settings Internal MAC is unique for each Ethernet communi...

Page 7: ...thernet settings o Event summary 3 2 Reporting Alarm Receiving Centre ARC reporting Reporting Primary and backup To have connection with Primary and Backup channels mark checkboxes Enable Fill in fields for Remote Host Remote Port Choose reporting protocol TCP or UDP Enable PING Time and set time between signals in seconds required for communication control Enter Encryption key six symbol hexadeci...

Page 8: ...authentication code This code is used when adding new system to the application and controlling remotely via TrikdisConfig software for more details refer to 5 TrikdisConfig remote control 3 4 Event Summary Input description Describe input by filling in fields these will be sent if Alarm Restore occurs o Partition o Contact ID can be customized or left default value o Zone No describe which zone w...

Page 9: ...ected via USB cable to a computer role indication will be gone from status bar If a configuration is done via USB cable unplug the USB cable click Disconnect to go back to the first window Installation process 4 1 Connect the communicator to the control panel using wiring diagram below 4 2 Optional connect sensors The communicator contains one input terminal IN1 for connection of sensors it can be...

Page 10: ... https www protegus eu login 2 Add the system to the Protegus press Select system next Add new system and enter the required data as shown below you can skip fields Name Address and fill it later TrikdisConfig Remote control Communicator E10Tv2 can be controlled remotely using TrikdisConfig software To do so follow steps below 1 Open TrikdisConfig 2 At the field Remote access in the field Unique I...

Page 11: ...mware file can be downloaded by registered user from www trikdis com under the download section of the E10Tv2 communicator 5 To save communicators parameters which were set earlier check box Preserve settings 6 Press Update F12 7 Wait for the prompt about the completed update to appear 8 Click OK in the prompted window Status bar Once the communicator parameters are read the status bar will displa...

Reviews: