Trigon Minipak 4000 Installation & Operation Instructions Download Page 3

Page 3

MP 4000

INTRODUCTION

INTRODUCTION

INTRODUCTION

INTRODUCTION

INTRODUCTION

USE OF THIS MANUAL

This manual contains all of the information required to
successfully install and program the Trigon MP4000.
If you are using this manual to install this unit, it is very
important for you to read the following sections in order:

You should read these instructions before you begin the
installation.  This will insure that everything is done
efficiently.

If you are using this manual as a programming guide
after the initial installation, you will find the TABLE
OF CONTENTS  helpful in locating the particular
programming procedure you desire.

PRODUCT OVERVIEW

PRODUCT OVERVIEW

PRODUCT OVERVIEW

PRODUCT OVERVIEW

PRODUCT OVERVIEW

Figure 1

Telephone Line  - 22 AWG;
Shielded or Twisted,
2 Conductor

Camera, Door or Gate

Secondary

Relay

Serial Printer

(18 AWG; Shielded, 3 Conductor)

Postal

Lock

Box

Primary
Output
Relay

Main Entrance

Power Cabling -
Shielded or Twisted,
2 Conductor,
18AWG  up to  250'
16AWG  up to  500'

Card Reader
(Interface Module Req'd)
18 AWG; Shielded,
4 to 6 Conductor

Alarm
Shunt

Relay

MINIPAK

4000

TRIGON ELECTRONICS
        ORANGE CA.

PUSH START

DIAL NUMBER

9.5"

3.0"

 12.5"

The TRIGON MP4000 is in itself a complete Access
Control Security System.  It makes use of an ordinary
telephone line to provide complete remote control of
an entrance point and/or its monitoring equipment.  It
allows visitors to make contact inside the building they
wish to enter.  Personnel inside the building answer the
incoming telephone call and, with a touch of a button
on their Touch-tone telephone, they grant or deny the
visitor ’s entrance.  Likewise, it allows tenants/
employees a means of direct entry via code or card.

Two relay outputs make it possible to control a camera
as well as a barrier.  Barriers may be latched open under
control of an on-board Time-of-day Clock.  Available
flush mount backboc as well as anoptional lighted hood
add to alternative mounting options.  Records of entry/
exit activity are made possible with a Serial Printer
Output.

Summary of Contents for Minipak 4000

Page 1: ...1 MP 4000 October 29 2004 255 Glider Circle Corona CA 92880 951 371 1730 FAX 951 371 2592 www TrigonElectronics com INSTALLATION OPERATION INSTRUCTIONS Minipak 4000 Multiple Resident Telephone Entry S...

Page 2: ...en Duration 7 Instruction Screen Duration 7 Set Inverse Screen Mode 7 Dense Mode 7 CLOCK CONTROL SCREEN Set Date and Time 7 Set Relay Backlight ON OFF Timing 7 Set Program Code 8 Master Erase 8 MESSAG...

Page 3: ...Entrance Power Cabling Shielded or Twisted 2 Conductor 18AWG up to 250 16AWG up to 500 Card Reader Interface Module Req d 18 AWG Shielded 4 to 6 Conductor Alarm Shunt Relay MINIPAK 4000 TRIGON ELECTRO...

Page 4: ...sure to use a bimetal thermal switch to prevent overheating during the summer months 1 Use the enclosed wiring diagram Fig 3 for wire connection information 2 Do not power any other device from the T...

Page 5: ...2 OUT which goes to pin 3 Rec Data of a printer RS232 port 3 BSY which goes to pin 20 Transmit Data of a printer RS232 port All access data is recorded to the printer 11 Postal Input Two screw termin...

Page 6: ...or six 5 second intervals 30 seconds Select the digit 1 9 that corresponds to the total number of gate intervals desired NOTE A 0 will allow Relay 1 or 2 to engage for a one second pulse CALL LENGTH C...

Page 7: ...ime you will leave this screen and go to Screen 3 Message Edit If you press the key you will move the Cursor down one line The numeric keys 0 9 are used to complete the required data inside the bracke...

Page 8: ...key the A letter is located on and 1 represents the fact A is the first letter on the key To make a B press 2 2 Again B is on the 2 key its second letter Spaces are made by pressing 1 1 The letter Q i...

Page 9: ...cursor positioned at the first entry code digit location Programming Continued RESIDENT CODE To program a listing for the electronic directory first assign a RESIDENT CODE for that tenant Only ONE li...

Page 10: ...the first position of any given listing Alphabetizing is automatic based on the first letter of each listing Look at this Example To Enter S M I T H J The letter S is on the 7 key of a Telephone Keypa...

Page 11: ...ter 8 to activate Relay 2 and disconnect Enter 9 to activate Relay 2 and continue conversation Rotary Telephones Dial 0 to activate Relay 1 and disconnect OPERATION OPERATION OPERATION OPERATION OPERA...

Page 12: ...rike Use low current strike 3 Unit transformer shared with another device i e door strike UNIT NOT DIALING 1 No phone number programmed under that resident code Reprogram and try again 2 Incorrect res...

Reviews: