background image

 

5

speaker relays and all three LED are flashing. Please power off the 

DWARF II

 completely by 

the mains switch 

(12) 

to reset the protection circuit. The 

DWARF II

 can be powered up 

again after approx. 10 seconds. If all LED are still flashing after the reset, there may be a  
defect in the output stage and the unit must be sent in for service. Please contact your 
authorized dealer, distributor or 

TRIGON ELEKTRONIK GmbH

 directly. 

 
If LED 

(3) 

flashes quickly

  

LED

 (4) 

flashes slower at the same time, an 

Overload 

occurred 

to the power amplifiers  and the speakers are turned off. The flashing of the LED stops 
after approx. 5 seconds and the speaker relays switches on again.   
Possible reasons for an overload are e.g. a too low speaker impedance or an over-regulation 
of the power amplifier expressed in a loud and distorted rendition. 
 
Should the operation 

temperature

 of the unit reach its maximum permissible value the 

speakers are deactivated and LED 

(3)

 flashes quickly. Once the temperature returns to 

normal design parameters, the speakers will be reactivated and the LED stops flashing. 
To supply the power amplifier in cooling down it is useful to  turn the volume control at the 
preamplifier to “Zero”. 
 
 
Sometimes it may happen, that the combination speaker and speaker cable does not suit 
very well to 

DWARF I

I and the power amplifiers start to oscillate in an inaudible level of 

frequency. In this case the power amplifiers warm up depending on the intensity of oscillation, 
because the power amplifiers emit now power  to the speakers. To protect  the power amplifier 
against the oscillation caused by external influences 

DWARF II

  is equipped with  protective  

electronics which turns off the speakers to stop oscillation immediately. During the deactivation 
of the speakers LED 

(4)

 flashes quickly. 

After approx. 5 seconds speakers are reactivated  again. If LED 

(4) 

starts flashing again quickly 

(and speakers are turned off again), please power off the 

DWARF II

 at the mains switch and 

use a different speaker cable. In most cases oscillation can be prevented thereby, provided that 
the now used cable has a less capacitive resp. inductive rate. 

 

Following an overview of all LED light sequences and their meaning in short form: 

 

DC-Offset:

 All LED are flashing, speaker is deactivated permanently 

Overload:

   LED 

(3) 

flashes quickly

, LED (2) 

flashes slower, the speaker

 

turns off short-term  

Temperature control: 

LED (3) flashes quickly, speakers are deactivated till the temperature 

of the power amplifier returns to normal 

       -     HF Oscillation:

  LED 

(4) 

flashes quickly and the speaker is deactivated  short-term

 

 

 
 

Specifications: 

 
 

Input Impedance 

 

 

: 47KOhm  

Input   

 

 

 

: 1x XLR Balanced 

Output  

 

 

 

: 1x Speaker, 1x Line 

Output Power  

 

 

: 1x 90W at 4 Ohm, 60W at 8 Ohm 

Signal Noise    

 

 

: 40µV  (A-weighted) 

Frequency Response  

 

: 20Hz – 150KHz      (-3dB) 

THD + N 

 

 

 

: <  0.02%  

Dimensions H x W x D 

 

: 59,5mm x 200mm x 330mm 

Weight 

 

 

 

 

: 5.2 kg 

Warranty 

 

 

 

: 3 years

 

 

 

                         

 

 

 

  

 
 
 
 
 

Reviews: