TY96/96A and TY97/97A VHF Radio Installation Manual
26 September 2018
01238-00
Issue AJ
______________________
Page 28
Trig Avionics Limited
11.
Environmental Qualification Forms
Nomenclature:
TY96 VHF Radio
Part Number:
01226-00-xx
ETSO:
2C169a, 2C128
Manufacturer:
Trig Avionics Limited
Address:
Heriot Watt Research Park, Edinburgh, Scotland, EH14 4AP
Conditions
DO-160G
Description of Conducted Tests
Temperature and Altitude
4.0
Equipment tested to Categories: A4, C4
Low temperature ground survival
4.5.1
-55°C
Low temperature operating
4.5.2
-20°C
High temperature operating
4.5.4
+55°C
High temperature short-time operating
4.5.3
+70°C
High temperature ground survival
4.5.3
+85°C
Loss of Cooling
4.5.5
Cooling air not required (+70°C operating without cooling air)
Altitude
4.6.1
55,000 feet
Decompression
4.6.2
8,000 to 55,000 feet in 15 seconds
Overpressure
4.6.3
-15000 feet
Temperature Variation
5.0
Equipment tested to Category C
Humidity
6.0
Equipment tested to Category A
Operational Shocks
7.2
Equipment tested to Category B
Crash Safety
7.3
Equipment tested to Category B
Vibration
8.0
Aircraft zone 2; type 3, 4, 5 to category S level M; type 1
(Helicopters) to category U level G
Explosion
9.0
Equipment identified as Category X
– no test required
Waterproofness
10.0
Equipment identified as Category X
– no test required
Fluids Susceptibility
11.0
Equipment identified as Category X
– no test required
Sand and Dust
12.0
Equipment identified as Category X
– no test required
Fungus
13.0
Equipment identified as Category X
– no test required
Salt Spray
14.0
Equipment identified as Category X
– no test required
Magnetic Effect
15.0
Equipment tested to Category Z
Power Input
16.0
Equipment tested to Category BX
Voltage Spike
17.0
Equipment tested to Category B
Audio frequency conducted susceptibility
18.0
Equipment tested to Category B
Induced signal susceptibility
19.0
Equipment tested to Category AC
Radio frequency susceptibility
20.0
Equipment tested to Category TT
Radio frequency emission
21.0
Equipment tested to Category B
Lightning induced transient susceptibility
22.0
Equipment tested to Category B2H2L2
Lightning direct effects
23.0
Equipment identified as Category X
– no test required
Icing
24.0
Equipment identified as Category X
– no test required
Electrostatic Discharge
25.0
Equipment tested to Category A
Fire, Flammability
26.0
Equipment identified as Category C
Summary of Contents for TY96