Tricolor LED PAR CAN User Instruction Download Page 3

 

3

LED PAR CAN                                            Introduction 

 

Unpacking: 

Thank you for purchasing our products.    Every unit has been thoroughly tested 

and has been shipped in perfect operating condition. Carefully check the shipping carton for 

damage that may have occurred during shipping. If the carton appears to be damaged, carefully 

inspect your fixture for any damage and be sure all accessories necessary to operate the unit has 

arrived intact. In the case damage has been found or parts are missing, save the carton and all 

packing materials. In the event a fixture must be returned to the factory. It is important that the 

fixture be returned in the original factory box and packing. 

 

Introduction:

 The unit is a DMX intelligent LED par can. This light can be used in a standalone 

mode or connected in a Master/Slave configuration. The unit can also be controlled via DMX 

controller. This light has four operating modes: Sound Active mode, stand alone mode, 

Master/Slave and DMX control mode. 

 

AC Power:

 

This fixture has an auto-switching power supply that can accommodate a wide range 

of input voltages. The only thing necessary to do before powering on the unit is to make sure the 

line voltage you are applying is within the range of accepted voltages. This fixture will 

accommodate between 90V and 240V AC. All fixtures must be powered directly off a switched 

circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit. Even if the rheostat or 

dimmer channel is used solely for a 0-100% switch.       

 

Safety Instructions: 

 

 

 

 

 

 

 

• To reduce the risk of electrical shock or fire, do not expose this unit   

 

rain or moisture 

• Do not spill water or other liquids into or on to your unit. 

• Be sure that the local power outlet match that of the required volt-   

 

age for your unit. 

• Do not attempt to operate this unit if the power cord has  been  

 

frayed or broken. Do not attempt to remove or break off the ground   

prong from the electrical cord. This prong is used to reduce the risk    

 

of electrical shock and fire in case of an internal short. 

• Disconnect from main power before making any type of connection. 

• Do not remove the cover under any conditions. There are no users   

serviceable parts inside. 

• Never operate this unit when its cover is removed. 

• Never plug this unit in to a dimmer pack 

•Always be sure to mount this unit in an area that will allow proper   

Please read these instructions carefully, which includes important 

information about the installation, usage and maintenance of this 

product? 

Summary of Contents for LED PAR CAN

Page 1: ...1 LED PAR CAN User Instruction ...

Page 2: ...2 FEATURE 3 SET UP 3 Pin to 5 Pin Conversion Chart Setting up a DMX Serial Data Link Master Slave Fixture Linking 4 OPERATING INSTRUCTIONS Operating modes Product overview Program Mode Sound Mode Master Slave Operation Master Slave Connections and Settings DMX Mode 5 DMX CHANNEL SUMMARY ...

Page 3: ...nit is to make sure the line voltage you are applying is within the range of accepted voltages This fixture will accommodate between 90V and 240V AC All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit Even if the rheostat or dimmer channel is used solely for a 0 100 switch Safety Instructions To reduce the risk of electr...

Page 4: ...to the appliance C The appliance has been exposed to rain or water D The appliance does not appear to operate normally or exhibits a marked change in performance Warning To prevent or reduce the risk of electrical shock or fire do not expose this unit to rain or moisture Caution There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufac...

Page 5: ... sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior Figure 3 XLR Pin Configuration Pin 1 Ground Pin 2 Data Compliment negative Pin...

Page 6: ...lowing fixture and so on Operating Modes You can use the unit in either a standalone mode or a master slave configuration there are 4 modes to choose from Program Mode Choose a static color color show color fade show or color cycle The speed of the show is adjustable You can also have the unit strobe in this mode Master Slave Mode Using the Master unit chooses your desired mode or program and conn...

Page 7: ...effect 2 If you have selected a static color press SET UP button to enter into the flash rate F 000 100 press UP and DOWN to adjust and select your desired flash rate 3 When you have chosen a color show 02 17 press SET UP button the display will show S000 S100 Press UP and DOWN button to adjust and set the speed When the display shows F000 F100 your desired program is running in strobe effect 4 Wh...

Page 8: ... plug in the fixture via the XLR connections to any standard DMX controller Press MODE button till DMX MODE display and press SET UP button to enter the DMX address and DMX mode selection and then press UP or DOWN buttons to adjust the DMX address and DMX mode The channels value refers to the following channel summary LED PAR CAN DMX Channels Summary 1 DIAGRAM I E A MENU B UP C DOWN D CONFIRM E DI...

Page 9: ...1 99 7 BEAT Music Activated 8 SLAV Slave accept and control according to master s signal 4 DMX 3 CHANNELS CH 1 RED CH 2 GREEN CH 3 BLUE 5 DMX 6 CHANNELS CH 1 RED CH 2 GREEN CH 3 BLUE CH 4 RED GREEN BLUE LINEAR 0 100 DIMMER CH 5 SPEED CONTROL WORKING WITH CH 6 CH 6 001 049 STROBE 050 99 COLOR SELECTION 100 149 GRADUAL 150 199 PULSE 200 249 CYCLE 250 255 MUSIC ACTIVATED KEY POINT Easy to operate fri...