19 - 25
4. Instruction
4-1
Operation
If lubrication is needed during the intermittence, please push the FEED button.
Make sure the power cable is disconnected before the installation or removal of the
system. Turn ON the power after more than twenty seconds of turning OFF.
The adaptor of the system for connecting the pipe is
without
one-way function for the
system. It is prohibited for changing to non-original set-up to avoid malfunction.
Note !! The set-up of intermittent time needs to be above five times than lubrication
time to prolong the life of the motor(the recommended minimum intermittent
time is 3-minute).
4-2 Lubricant Filling
Always keep the oil level between the level of 30% and 80% of the tank height. Float switch
will output signal when the remainder of the lubricant drops below the height if the float
switch, and it is time to fill the tank. Remove the oil tank cap (Fig. D), you can fill the
tank.
Attention!
Recycled lubricant is
PROHIBITED
5. Maintenance
Trico Corporation centralized lubrication systems are of low maintenance. However, related
connection needs to be reviewed if properly fitted to secure the proper function of the system.
Please clean periodically the oil tank of Trico Corporation
centralized lubrications. If the user
wants to clean the tank, please
TURN OFF
the system first and remove the bolts on the tank
to separate the tank for cleaning. After cleaning the tank, please fasten the bolts to fix the
tank.
Please follow below requirements,
Restart the lubricator after 20 sec. of turning off to stabilize the performance of the lubricator.
It is prohibited for changing to non-original set-up to avoid malfunction.
The One-way adapter cannot be applied.