PREPARING CABLE
We recommend you use a new length of cable to
ensure your safety.
l
Ensure you have the correct length of cable
appropriate to the wiring method you are using.
When fitting new cable allow sufficient cable for
removal of the unit at a later date, should it be
necessary.
l
Score, but do not cut through, around the
sheathing with a knife 100mm (4in) from each
end of the cable and break through to the
encased wires by bending the cable backwards
and forwards to fatigue the sheathing.
l
Carefully score down from each end of the cable
sheathing along the length of the bare earth wire (if a
cut was made along the length of the live and neutral
wires, it might cut into their sheathing) to the cuts
already made.
l
Carefully prise open the sheathing at each end of
the cable to expose the encased wiring.
TO REMOVE COVER OF MAINS TERMINAL
From the rear of the cooker, remove mains input
terminal cover to gain access to terminal block.
l
First remove retaining screw with pozidrive
screwdriver. See Fig. 5.
l
Prise cover loose using screwdriver in position
(1) then lever off with screwdriver in position (2)
at either side. See Fig. 6.
l
Lift cover and remove screw from cable clamp.
See Fig. 7.
11
Fig. 5
MAKING THE ELECTRICAL CONNECTIONS
Important: Switch off at mains, miniature circuit
breaker and, if appropriate, remove fuse before
commencing any electrical work.
Fig. 7
Fig. 6
Pozidrive
Screwdriver
Terminal
Screwdriver
(2)
(1)
Cable
Clamping
Block