23
SOLIDO:
Language:
Select English
Set time and date:
Set the current time and date
Password:
Commissioning password is 7682
Type of plant:
Select SOLIDO N/D
Number of Persons:
Input the number of normal residents in your property (between
2 and 6)
Compressor:
80 l/min
Winter-eco:
No
Test mode:
The control unit switches on each of the lifters in turn; press any
button to end the test run.
Settings ok:
Yes/No? (Yes: operation starts, No: back to the factory default state)
Test mode:
The basic screen then appears, and the control unit starts the first
cycle.
Green LED, top:
Indicates operational readiness (connected to the mains)
Red LED, bottom:
Flashes to indicate an alarm message
Note: After commissioning start-up phase “start 150%” will be automatically activated, then
during 120 days the aeration time is increased to 150% of set value.