27
All vehicles incorporate a Truma S3002 3kw
gas heater.
Igniting the heater
Before operating the heater for the first time
ensure that the batteries are fitted to the ignition
unit, and that the gas cylinder, and isolation valve
are turned on.
Turn on the control knob to the desired thermostat
setting (from 1 to 9) and press down as far as the
stop. Ignition will take place automatically (audible
clicking noise) until the flame ignites. Keep the
control knob pressed down for a further ten
seconds to allow the safety pilot to operate.
If the flame should go out then automatic ignition
will occur immediately during the closing time of
the safety pilot (approximately 30 seconds).
If there is no flame present the igniter will
continue to operate until the control knob is
switched to (0).
Truma Ultraheat (230V Mains Operation) –
Optional Fitment
Your Truma S3002 heater may be fitted with the
optional 2kw mains element. If the two energy
sources are used simultaneously, this gives the
heater a maximum output of 5kw.
Before switching on ensure that the electrical fuse
spur protecting the ultraheat is in the on position.
The position of this switch varies from model to
model so please familiarise yourself with the
location of this switch before using your vehicle
for the first time.
To switch the unit on turn the rotary outer switch
to the desired heat output level
(500W, 1000W or 2000W).
Set the central thermostat knob to the desired
room temperature (1 to 9). The actual setting of
the thermostat must be determined individually
depending on the heating requirements for
each customer.
To switch the unit off rotate the outer switch to
the off (0) position.
Trumavent Blown Air Heating System –
Optional Fitment
The Trumavent blown air system distributes warm
air through the blown air ducting throughout
the vehicle.
Set the rotary control on top of the S3002 to
either manual or automatic setting.
On the manual setting the speed of the blown air
fan is controlled via the central control knob that
gives settings from 1 to 5 (5 being the highest).
On automatic setting the heat output is steadily
adjusted to the respective heat emission from
the heater. The maximum setting of the fan
can be set by the central control knob and
the output will vary between this value and
the slow running setting.
To turn off the blown air system rotate the outer
control to the central off position.
Owners Handbook
Truma S3002
Vehicle Space Heater Truma S3002
Summary of Contents for IMALA
Page 2: ...Owners Handbook...
Page 55: ...Cable Colour Chart...
Page 56: ...55 Power Circuits Owners Handbook...
Page 57: ...Road Lighting...
Page 58: ...57 Consumer Circuits Floor Owners Handbook...
Page 59: ...Consumer Circuits Roof...
Page 60: ...59 230v Circuits Owners Handbook...
Page 61: ...Notes...