13
GHV 500 Serie
BEWARE:
You must adhere to the Safety precautions of EN 60728
-11
Before you start working on the installation, turn off Mains Power to the circuit.
Only let an authorized Electrician do the Mains power plug installation if needed.
Never do Installation or Repair during Thunder Storms.
Always ground the network using the Grounding Terminal of the unit (Diameter
min. 4 mm
2
) or using the Building Grounding Terminal.
Before you start working on the installation, turn off Mains Power to the circuit.!
Observe the safety precautions!
Mount the Amplifier...
Horizontal, free on the wall and so that the convection cooling of the unit
is not compromized.
On non
-
flammable material (Concrete or Brick Wall)
In a dustfree environment, protected against moisture and fluid.
(Drop– and spraywater)
Not in a spot with direct Sun radiation (e.g.. On the Roof)
Not directly along with Heat Sources (e.g. Heating Room)
In compliance with the highest allowed working Temperature
(measured at the Airflow under the Amplifier)
Wallmounting:
Fasten the Amplifier according to its measurements (See Fig. 1.) on the wall.
(Screws-ø max. 4.8 mm, Distance between holes 158 mm)
Create a Grounding potential using the screw A and a sufficient fitted and stable
cable (Diameter min. 4 mm
2
)
Connect the RF
-
Input B and the RF
-
Output C. Make sure you get perfect
connection between Coax cable and Connector.
Turn on the Mains Power to the circuit again.
Fig. 1 Mounting
Installation
English
2.3 Safety
precautions
3. Installation
3.1 Local setup
3.2 Mounting
158 mm