11
Information mode
When button ‘B’ is pressed shortly in standby mode, information display mode will be activated.
Scroll through items by turning the dial E
. Press the dial to view the currently selected item.
Index
Parameter
Description
A: Li or A: GA
DHW Flow
Current flow value(Li: L/m, GA: GPM)
b: Fr
Fan rpm
Current fan rpm value
C: Lc
Lock Mode
Lock mode is (On) or (oFF)
d: OP
OP Temperature
Current Operating Temperature
E: dH
DHW temperature
Current DHW temperature
F: Eh
Exhaust Temperature
Current Exhaust temperature
h: In
Inlet Temperature
Current Inlet Temperature
L:rt
Running Time
Display Running Time
L:rt
1: PH
Power Supply Time
Power Supply Time: 100 hour increments
2: rh
Burner Operating Time
Burner Operating Time: 1 hour increments
3: rH
Burner Operating Time
Burner Operating Time: 1,000 hour increments
4: It
Ignition Attempts Number
Ignition Attempts Number: 10 times unit displayed
5: IH
Ignition Attempts Number
Ignition Attempts Number: 10,000 times unit
displayed
J: AG
AGM Position
AGM calibration
Method of Operation