6
This boiler must only be installed by a CORGI-
registered engineer and be in accordance with any
local building regulations. Where no specific
instruction is given, reference should be made to the
relevant British Standards Codes of Practice.
The installation must also comply with the following
regulations and standards:
The Building Regulations Part L
I.E.E. Wiring Regulations
Gas Safety (Installation and Use) Requirements
Local Water Undertaking bylaws.
BS 6891 – Gas Installations
BS 5482 – Installation of LPG
IS 813 – Installation of Gas Appliance
(Ireland only)
BS 5546 – Installation of Hot Water Supplies for
Domestic Purposes
BS 5449 – Flues and Ventilation
BS 4814 – Specification for Expansion Vessels for
Sealed Hot Water Heating Systems
BS 6798 – Measurement of Emitted Noise
BS 5449 – Forced Circulation Hot Water Central
Heating Systems
BS 7074 – Expansion Vessels and Ancilliary
Equipment for Sealed Water Systems
BS 7593 – Treatment of Water in Domestic Hot
Water Central Heating Systems
BS 7671 – Electrical Wiring Regulations
BS EN 1264 Part 4 – Installation of Floor Heating,
Systems and Components.
Incorrect installation may cause harm to people,
animals and property. The manufacturer is not liable
for damage caused by incorrect installation and by
non-observance of these instructions.
The addition of anything which may interfere with the
normal operation of the boiler without the written
permission of Trianco Ltd could invalidate the
appliance guarantee and infringe the Gas Safety
(Installation and Use) Regulations.
-
Wall-mounted appliance. Siting not dependant
upon room size.
-
Multi-function display
-
Natural gas models are low-emission
-
Automatic ignition
-
Modulating Output
-
Full safety systems, with flame ionisation
monitoring and temperature sensors
-
Concentric flue with CO/CO
2
test point
-
Regulated-speed fan
-
Pre-mix burner
-
Central heating temperature control
-
DHW temperature control (CB Model)
-
Three-speed circulating pump with auto vent
-
Pressure gauge, relief valve, expansion vessel
-
Hot water priority circuit
-
Plate-type heat exchanger (CB Model)
-
Integral condensate trap
If antifreeze substances are to be used in the system,
always check with the manufacturer that they are
compatible with the aluminium which forms the main
body of the boiler heat exchanger. Due to
its corrosive nature,
do not
use antifreeze
products which contain ETHYLENE
GLYCOL.
A suitable antifreeze liquid will prevent rust and the
formation of scale.
Periodically check the pH value of the system water,
replacing as necessary when this falls below that
stipulated by the antifreeze manufacturer.
Do not mix different types of antifreeze.
Trianco cannot be held liable for damage caused to
the boiler or water system as a result of the incorrect
use of antifreeze or other additives.
1.5 USE OF ANTIFREEZE PRODUCTS
1.3 STANDARDS AND REGULATIONS
1.4 DESCRIPTION OF APPLIANCE
Summary of Contents for TRISTAR OPTIMA JUNIOR K CB
Page 2: ...2...
Page 4: ...4...
Page 7: ...7 2 TECHNICAL SPECIFICATION...
Page 9: ...9 2 2 WALL MOUNTING TEMPLATE FIG 2...
Page 28: ...28 6 16 VERTICAL BALANCED FLUE SCHEMATIC FIG 39...
Page 32: ...32...
Page 42: ...42...
Page 43: ...43...
Page 44: ...44 Issue 1 Rev 0 July 2005 Item No 510062 LB 1480 01 09 2005...