Tri-Tronics Ultrasonic Clear Label Sensor Manual Download Page 6

www.ttco.com • 800-237-0946

2-112

2

S

pecialty 

Application Photoelectric Sensors

Clear Label Sensor

SUPPLY VOLTAGE

• 12 to 30 VDC

• Polarity Protected

Note: For use in Class 2 Circuits

CURRENT REQUIREMENTS

• 95mA @ 12 VDC, 45mA @ 30 VDC

DIGITAL OUTPUTS

• (1) NPN and (1) PNP open collector 

output 150mA Max; <2V Residual

Voltage

(Note: On CLSC-1M8, NPN & PNP are

software selectable).

• All outputs are continuously short

circuit protected

REMOTE AUTOSET INPUT 

• Momentary sinking or sourcing

input;

1.2mA max; Software Selectable

DIAGNOSTIC INDICATORS

• OLED Graphic Display - Includes

Contrast Indicator, Numerical

Display, Set Point and Trigger Point,

and all sensor options and modes.

• Red LED Output Indicator–

Illuminates when the sensor’s

output transistors are “ON”. 

Note: If output LED flashes on power

up, a short circuit condition exists.

PUSHBUTTON CONTROL

• Three (3) push button controls

• Gap (for Gap AUTOSET)

• Label (for multi-layered labels)

• Menu (for accessing Options)

HYSTERESIS

• Dynamic – adjusted by AUTOSET

RESPONSE TIME

• 200µs

REPEATABILITY

• 125µs

AMBIENT TEMPERATURE

• 4°C to 50°C (39°F to 122°F)

RUGGED CONSTRUCTION

• Chemical resistant, high impact

Aluminum housing

• Waterproof ratings: NEMA 4X, 6P

and IP65

• Conforms to heavy industry grade

CE requirements

THRESHOLD SET

• 1-Point, 2-Point, or Dynamic

AUTOSET; manually or remotely.

THRESHOLD ADJUST

• Manual or AUTO Adjust

OUTPUT TIMERS

• On Delay, Off Delay, One Shot, or

Debounce (Advanced Option,

software selectable).

CONNECTOR

• M12 5-Pin, M8 4-Pin, or 6’ (1.8m)

Shielded Cable

RoHS Compliant

Product subject to change without notice

Specifications

(2 )

(2 )

3 0   V D C

1 2  T o

M8 Wiring

O u tput

N P N   (S IN K IN G )  IN P U T   A C T IV A T E D   B Y   C O N N E C T IN G   T O   N E G A T IV E
P N P  (S O U R C IN G )  IN P U T   A C T IV A T E D   B Y  C O N N E C T IN G  T O  P O S IT IV E

(2 ) - 

(1 ) - 

N P N   (S IN K IN G )  O U T P U T   LO A D   T E R M IN A T E D   T O   P O S IT IV E
P N P   (S O U R C IN G )  O U T P U T   L O A D   T E R M IN A T E D   T O   N E G A T IV E

(1 )

L O A D

P os

R e m o te
A uto set

N e g

B ro w n *  (1)

R e d

G re en
B la c k *  (4)

W hite
W h ite *  (2)

B lu e *  (3)

B lack

L O A D

L O A D

B lue
G ra y *  (5)

P os

N P N

(S ink)

P N P

(S o u rce)

N e g

R e m o te
A uto set

3 0   V D C

1 2  T o

M12 and Cable Wiring

B ro w n   (1)

B la ck   (4)

W h ite   (2)

B lu e   (3)

Wht

Load

NP

N

Load

PN

P

(2)

Br

n

(1)

Bl

k

(4)

Bl

u

(3)

Gr

y

(5)

0.

250"

 [6

.3

m

m

]

0.

551"

 [1

4

.0

m

m

]

0 .3 6 0 "

 [9 .1 m m ]

2 .7 6 7 "

 [7 0 .3 m m ]

0 .7 6 7 "

  [1 9 .5 m m ]

3 .1 1 3 "

  [7 9 .1 m m ]

0.

158"

 [

4

.0

mm]

3 .8 9 3 "

 [9 8 .9 m m ]

2 X   Ø 0 .2 0 5 "

  [2 X  5 .2 0 m m ]

OUTPUT

OUTPUT

S

O

T

U

A

T

E

A

G

P

A

L

B

E

L

E

N

M

U

OUT

PUT

S

O

T

U

A

T

E

A

G

P

A

L

B

E

L

E

N

M

U

S

O

T

U

A

T

E

A

G

P

A

L

B

E

L

E

N

M

U

4 .5 2 2 "

 [1 1 4 .8 6 m m ]

4 .3 3 2 "

 [1 1 0 .0 3 m m ]

4 .1 8 1 "

 [1 0 6 .2 0 m m ]

B ro w n   (1 )

B la ck  (4 )

W h ite   (2 )

B lu e   (3 )

L O A D

L O A D

P o s

N P N

(S in k)

P N P

(S o u rce )

N e g

3 0   V D C

1 2   T o

CLSC-1M8LE Wiring

M8 & M8LE

MODELS

M12

MODELS

CABLED

MODELS

M 8   M a le 

C o n n e ctor

1   -  P os itive

2  - Remote AUTOSET
3  - N e gative
4  - Output

4

3

2

1

* - S en so rs  w ith  co nn ec to rs

1   -  P os itive

2   -  N P N
3  - N e gative
4   -  P N P
5  - R e m o te AUTOSET

M 1 2   M a le 

C o n n e ctor

2

3

1

4

5

M 8 LE  M a le 
C o n n e ctor

1   -  P os itive

2  - NPN
3  - N e gative
4  - PNP

4

3

2

1

0 .4 7 2 "

 [1 2 .0 m m ]

0 .3 6 0 "

 [9 .1 m m ]

2 X   6 -3 2   M o u n tin g  
H o le s,  0 .1 5 0 " 
[3 .8 m m ] D e e p

M8 & M8LE
MODELS

M12 MODELS

1.

441"

 [3

6

.6

m

m

]

0 .8 5 0 "

 [2 1 .6 m m ]

1.

944"

 [4

9

.4

m

m

]

2.

022"

 [

5

1

.4

mm]

0.

676"

 [

1

7

.2

mm]

1.

110"

 [

2

8

.2

mm]

Connections and Dimensions

Ultrasonic Clear Label Sensor

NOTE: Side and bottom mounting holes
are compatible with LER models.

Summary of Contents for Ultrasonic Clear Label Sensor

Page 1: ...www ttco com 800 237 0946 2 107 2 Specialty Application Photoelectric Sensors Clear Label Sensor Clear Label Sensor ...

Page 2: ...nsor that provides visual confirmation of proper setup and function a simple solution with the ability to accurately adjust for repeatable and reliable performance Now CONFIDENTLY walk away from the labeling line KNOWING the throughput is at peak performance and trouble free Features OLED Alphanumeric Display 10 Bar Graphic Contrast Indicator Static and Dynamic Numerical Display One button AUTOSET...

Page 3: ...Application Photoelectric Sensors Clear Label Sensor Applications SEAL CREASE TAPE Double Sheet Detection Splice Detection Clear Label Application Heat Seal Detection High Speed Rewinding Clear Metal Foil or Paper Labels Fold or Crease Detection ...

Page 4: ...s This option allows the user to make that determination and provides flexibility in real world conditions For visual preference the Display Orientation allows the user to flip the screen for a more user friendly visibility Menu Options The Sensor Scope is also an Advanced Option and allows the user to visually see how the sensor is detecting the target Whether the labels or web materials are inco...

Page 5: ...ew Menu Options MENU BUTTON 1 Push and Hold for 1 second to enter Menu Options 2 Tap to scroll through Menu options 3 Hold during power up for additional Menu Options Timers and Factory Diagnostics or sensor scope 1 Select Sensor Ultrasonic Clear Label Sensor 2 Select Cable or Connector Blank 6 1 8m Cable C Connector M12 5 Pin Standard 3 Select Connector Type 1 Standard M12 Connector see 2 Include...

Page 6: ... Pin M8 4 Pin or 6 1 8m Shielded Cable RoHS Compliant Product subject to change without notice Specifications 2 2 30 VDC 12 To M8 Wiring Output NPN SINKING INPUT ACTIVATED BY CONNECTING TO NEGATIVE PNP SOURCING INPUT ACTIVATED BY CONNECTING TO POSITIVE 2 1 NPN SINKING OUTPUT LOAD TERMINATED TO POSITIVE PNP SOURCING OUTPUT LOAD TERM INATED TO NEGATIVE 1 LOAD Pos Rem ote Autoset Neg Brown 1 Red Gree...

Reviews: