Gap Set: Pulse once, 40ms to 400ms.
Label Set: Pulse twice, 40ms to 400ms, with 40ms to 400ms idle time between pulses.
Dynamic Set: Hold Remote Input on for more than 750ms, pull labels and gaps through sensor, release Remote Input
line and sensor returns to Run mode.
Note: Waveforms shown correspond to PNP input mode.
3
Remote Input Signals
Ultrasonic Clear
Label Sensor
Blank = 6’ Cable
C = Connector
-1
-1M8
-1M8LE
Example:
CLS C -1
How to Specify
1.
Select Sensor:
Ultrasonic Clear Label Sensor
2.
Select Cable:
Blank = 6’ (1.8m) Cable
C = Connector M12, 5-Pin
(Standard)
3.
Select Connector:
-1 = Standard M12 Connector, see #2
Includes both NPN and PNP
-1M8 = M8, 4-Pin Connector
NPN/PNP Software Selectable
-1M8LE = Wired like LER
Factory Reset
Input Mode
(-1, -1M8 models only)
Timer Features
Factory Diagnostics/Sensor Scope
Returns to Main Screen
Advanced Options
To access Advance Options, press and
hold the Menu button during power up.
Press the Menu button to move from
screen to screen.
Press either the
_ or
+ button to select.
Press either the
_ or
+ button to initiate factory reset.
Note: Advanced Option screen will time out in 5
minutes.
Press either the
_ or
+ button to toggle to PNP / Source
or NPN / Sink.
Press either the
_ or
+ button to toggle to Enable or
Disable.
Press either the
_ or
+ button to toggle to Enable or
Disable.