(**Advanced Option)

Press either the 

_ or 

+ button to start a Dynamic Set; pull labels and gaps through sensor;

press either the 

_ or 

+ button to complete.

Sensor exits to run mode and should be setup and ready for operation.

Change from off to on by momentarily pressing either the 

_ or 

+ button. The Auto adjust

evaluates signal levels and makes automatic adjustments to keep the sensor in optimum
response levels.

Change from GAP (     ) to LABEL (     ) by momentarily pressing either the 

_ or 

+ button.

Output will toggle back and forth in this mode.

= Output on the Label
= Output in the Gap

Momentarily press either the 

_ or 

+ button to toggle orientation.

Press Menu for Detailed Setup

This option allows the operator to visually inspect the current setup for repeatability. The
sensor scope will also reveal any nominal setup issues or sensitivities to label or gap
thickness changes.
Momentarily press the 

_ button to shorten the time between signals. Momentarily press the 

+

button to lengthen the time between signals.

(**Advanced Option)

Off Delay: Outputs stay
on for set time after
duration of input.

On Delay: Outputs turn
on when input exceeds
set time

One Shot: Outputs turn
on for set time when
triggered by input

Debounce: Outputs are
stabilized and held in
current state for
duration of time setting

PRESS 

the 

+ button

PRESS 

the 

_ button

  Run Mode
Hold  - : Gap Set
Hold  + : Label Set
Tap +/- : Threshold

  Factory Menu
Hold Menu on Power Up
for more Options

  Support
Tri-Tronics Tampa, FL
www.ttco.com/cls
[email protected]       

  Dynamic Set
Tap Menu Button
Tap +/- to Start
Advance 3+ Labels
Tap +/- to End

  Remote Imput
Tap 1x : Gap Set
Tap 2x : Label Set*
Hold   : Dynamic Set

  Label Set
Can be used after a
Gap/Dyn Set to set
max label thickness

  Support
Tri-Tronics Tampa, FL
www.ttco.com/cls
[email protected]       

PRESS 

the 

+ button

PRESS 

the 

_ button

Press the the 

_ button to scroll down through simple setup and options instructions.

Press the the 

+ button to scroll up.

Momentarily press either the 

_ or 

+ button to toggle from Lock (    ) to Unlock (no symbol).

Useful for tamper-free operation.

Summary of Contents for M8

Page 1: ...Diagnostics or sensor scope Signal Strength Threshold Number AUTO Adjust Mode Locked Contrast Indicator Output ON Gap Label Setup Instructions Simple Setup Start Put the Gap in view press and hold the AUTOSET GAP button for two seconds Gap Set will be displayed when complete This will result in a perfect setup 99 of the time If you have any false triggers put the Label in view push and hold the AU...

Page 2: ...ime between signals Momentarily press the button to lengthen the time between signals Advanced Option Off Delay Outputs stay on for set time after duration of input On Delay Outputs turn on when input exceeds set time One Shot Outputs turn on for set time when triggered by input Debounce Outputs are stabilized and held in current state for duration of time setting PRESS the button PRESS the _ butt...

Page 3: ...rd 3 Select Connector 1 Standard M12 Connector see 2 Includes both NPN and PNP 1M8 M8 4 Pin Connector NPN PNP Software Selectable 1M8LE Wired like LER Factory Reset Input Mode 1 1M8 models only Timer Features Factory Diagnostics Sensor Scope Returns to Main Screen Advanced Options To access Advance Options press and hold the Menu button during power up Press the Menu button to move from screen to ...

Page 4: ...6m m 0 850 21 6mm 1 944 4 9 4m m 2 022 5 1 4m m 0 676 1 7 2m m 1 110 2 8 2m m SUPPLY VOLTAGE 12 to 30 VDC Polarity Protected Note For use in Class 2 Circuits CURRENT REQUIREMENTS 95mA 12 VDC 45mA 30 VDC DIGITAL OUTPUTS 1 NPN and 1 PNP open collector output 150mA Max 2V Residual Voltage Note On CLSC 1M8 NPN PNP are software selectable All outputs are continuously short circuit protected REMOTE AUTO...

Reviews: