24. Take measurements from the pipe OD to the Housing ID or use a dial indicator
to sweep around the pipe’s outside diameter.
25.
Adjust the Clamping Pads so that the measurements at opposing Clamping
Pads are the same.
General Machining Sequence
1.
To set Tool Bits, refer to the section on Tool Bit Setup.
2. Install the Air Motor into the drive socket and bolt it to the Clamshell. Check that
the air supply filter/regulator/lubricator is installed and set properly.
WARNING
WARNING: The Motor Mount reacts to the torque of the Air Motor only when the Motor
Hold-down Bolt is in place.
3.
Check that the air supply filter/regulator/lubricator is installed and set properly
4.
Select one of the five orientations to provide the most clearance for the Air Motor.
5.
Check for proper alignment of the Feed Sprockets.
Figure: 10. Air Motor Alternate Positions
1
2
3
4
5