Page 14
TPSi1085 User Guide
Rev 11/29
Installation
The TPSi1085 features quick-disconnect socket terminals for easy installation. The screw terminal
plugs for CN1 and CN3 accept 28 to 16 AWG wires.
Connection Diagram
The power outputs are isolated from the input supply up to 2250V.
Installation
Note
ISOCOM (CN1-2, CN1-5, & CN1-8) refers to the isolated output commons. CN1-9 (SDin) and CN1-10
(PS-STAT) are referenced to COM (CN3-2), the non-isolated input common
CAuTION
There is an addi5VDC and ISOCOM connector to adequately distribute the current if a
heavy load requires more than 8A (max. rating of terminal block)
CAuTION
If the remote shutdown control is not used, SDin (CN1-9) MUST be connected to the input power (CN3-1)
INPUT
SUPPLY
Controller
+3.3VDC
+5VDC
COM
9V-33V
Shutdown
Power
Failure
ISOCOM
ISOCOM
OUTPUT
LOAD
OUTPUT
LOAD
1
CN1
2
3
4
5
6
7
8
9
1
2
10
CN3
CONTROLLER
EXTERNAL
2
See
CAUTION