Page 11
TPSi1085 User Guide
Rev 11/29
Connectors
Note
PS-STAT (CN1-10) is
referenced to the input
COM (CN3-2)
Power Supply
Status (PS-STAT)
Opto-Coupler
MCU
COM
COM
TOP VIEW
1
2
3
4
5
6
7
8
9
10
+3.3VDC
+5VDC
+5VDC
ISOCOM
ISOCOM
SDin
PS-STAT
CN1
CAuTION
Although the TPSi1085 has reverse polarity protection, please ensure that the polarities are correct in order to avoid
damaging the input power supply. Supply must be correctly fused.
INPuT POWER (CN3)
CN3 is the input power connector. The input range is +9V to +33V DC. For enhanced protection, the
TPSi1085 provides active input clamping, transient suppressors, current limiting, and reverse polarity
protection. See the Protection Features section for more information. The quick-disconnect screw
terminal block is intended for 28 to 16 AWG wires.
Note
The terminal socket is Phoenix
1879285 which mates with
screw terminal block plugs,
Phoenix 1827703
2
1
+9V to +33V DC
COM
TOP VIEW
CN3
POWER SuPPLY STATuS (CN1-10)
The Power Supply Status (PS-STAT) output sends an active low signal when the input voltage is
outside of the range, +9V to +33V DC, and when the outputs are turned off. Once the input voltage
returns within the range and the power outputs turn on, the PS-STAT signal will turn off. The quick-
disconnect screw terminal block is intended for 28 to 16 AWG wires.