LIMITED WARRANTY 

 
 
All ECU products are warranted against defects in workmanship and materials for 12 months from 
date of installation. In the absence of suitable proof of date of installation (Bill of Sale), the specified 
warranty period will commence 30 days after the date of manufacture. This constitutes the only 
warranty in connection with this sale, and is in lieu of all other warranties, expressed or implied, 
written, or oral. 

THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY OR 

FITNESS FOR A PARTICULAR PURPOSE THAT APPLY TO THIS SALE.

 The circulator 

pump cartridge has a three-year limited warranty. The Trevor-Martin Corporation heat exchanger has 
a five-year limited warranty. 
 
No employee, agent, dealer or other person is authorized to give any warranties on behalf of Trevor-
Martin Corporation, nor to assume for Trevor-Martin Corporation any other liability in connection 
with any of their products, except as authorized by an officer of Trevor-Martin Corporation, in a 
signed written document. Units not protected against freezing are not warranted. 
 

LIMITATION OF REMEDY 

 
Trevor-Martin Corporation will replace or repair, at Trevor-Martin Corporations option, F.O.B. 
Factory, freight prepaid, any ECU product, defective in workmanship or material if such product is 
returned to our plant, freight prepaid, within 12 months of date of installation. It is agreed that such 
replacement or repair is the exclusive remedy available from Trevor-Martin Corporation, should any 
of our products prove to be defective. Trevor-Martin Corporation is not liable for damage of any sort 
whatsoever, including incidental and consequential damages. Product returns, under the terms of this 
warranty, must be approved by Trevor-Martin Corporation. Products or parts thereof replaced or 
repaired under the conditions of this warranty will be returned, transportation charges prepaid within 
the United States by best and most economical means.

 

 

 

4151 -112TH TERRACE N., CLEARWATER, FLORIDA 33762 PHONE: (727) 573-1490 FAX: (727)572-9350 

Summary of Contents for HR06

Page 1: ...ith tubes down and be above the height of the compressor Never with tubes upward or horizontally pad mounted 6 Recover refrigerant charge Cut hot gas line as close as practical to compressor before the four way valve on heat pumps Cut openings in condensing unit for hot gas lines Attach Gas In line to compressor discharge line Attach Gas Out line to other side of cut leading to condenser coil This...

Page 2: ...tric schematic above as a guide Between the ECU and 230v power disconnect run two 2 14 wires with ground in liquid tight cable 13 The piping and wiring are now complete Turn on water to heater With a hot water faucet open allow tank to fill When filled bleed all air from water circuit Loosen plug at center of pump optional to bleed air and verify water to bearings Start the air conditioning unit a...

Page 3: ... solid flow of water is observed c If this measure does not solve the problem check for mechanical damage to the lines d If this check does not provide a solution call your dealer and ask for a serviceman to give the installation a complete technical check 2 If the ECU is circulating but the production is below normal there are two possibilities a If the unit is three or more years old mineral bui...

Page 4: ... products except as authorized by an officer of Trevor Martin Corporation in a signed written document Units not protected against freezing are not warranted LIMITATION OF REMEDY Trevor Martin Corporation will replace or repair at Trevor Martin Corporations option F O B Factory freight prepaid any ECU product defective in workmanship or material if such product is returned to our plant freight pre...

Reviews: