45
CONTROL PANEL
SIGNALING OF THE WORKING PHASES AND ANOMALIES
POWER ON
PUMP ON
FAILURE
RESTART
Green led
Yellow led
Red led
Button
INSTALLATION AND STARTUP
EXAMPLE OF INSTALLATION
OPTIONALS
To operate, it must be connected to the power supply line of the pump.
For this reason, the power supply of the pump must be inserted in the device, which is then connected to the power point.
In case of water shortage, the device stops the pump protecting it from dry running. This failure is indicated with the blinking red Failure led.
In case of the current absorption exceeding 8 Ampere (or 10 Ampere for Logicstop Plus version), the device stops the pump motor and protects it against over-
current. This failure is indicated with the red Failure led on.
To restore normal operation to the device and the system simply press the red Restart button.
In case of a temporary blackout, the device will automatically rearm once the electricity returns.
LOGICSTOP IP65 / LOGICSTOP IP65 PLUS
- Version with IP65 degree protection of Logicstop and Logicstop Plus versions (see picture).
LOGICSTOP “AUSTRALIA”
- Version with Australian plug/socket.
LOGICSTOP INTEGRATO
- The “on-board” version of Logicstop inserted directly into the terminal box cover of the
pump. Only made on request.
Device energized
Pump running
Water shortage
Motor data acquisition
Overcurrent
Reset after failure
blinking
on
on
on
SCHUKO PLUG / SOCKET
LOGICSTOP / LOGICSTOP PLUS