TRENDnet TE-500plus User Manual Download Page 9

 

hub or an Ethernet switch, you should use a crossver cable, or 
make the connection using the Uplink jack. 

Uplink Jack 

The Uplink jack is an MDI-II jack, which means you can 
connect the hub to an Ethernet device’s (i.e. Hub or Switch) 
MDI-X port using straight-through cable.   

Port1 and the Uplink port is really the same port, except their 
pinouts are different. 

Do not use both Port-1 (1X) and the 

Uplink port at the same time. 

When uplinking hubs together, please do not exceed the 
“4-repeater (hub) count, 3 segments, and 2 populated 
segments” Ethernet connection rule. Basically, you can only 
uplink 4 hubs together using the UTP cable. The maximum 
CAT3, 4, or 5 twisted pair cable distance between two Ethernet 
devices is 100 meters. If you have question about this rule, 
please contact our support department at 
[email protected]

BNC Port 

(TE910

plus

 only) 

To connect the 10Base-2 network, attach the thin coax cable’s 
BNC “T Connector” to the BNC port. Terminate the open end 
of the “T Connector” with a 50 Ohms Terminator. The coax 
cable should be marked RG58U or RG58 A/U, the maximum 
cable length between the two terminators is 185 meters, and 
you can connect up to 30 nodes on this  cable. 

Power Jack 

For connecting the External power adapter. 

 

Summary of Contents for TE-500plus

Page 1: ...TE 500plus TE 800plus TE 910plus Palm Size 10Base T Ethernet Hub User s Guide ...

Page 2: ......

Page 3: ...es uses and can radiate radio frequency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domesti...

Page 4: ...EAR PANEL OF PALM SIZE HUBS 3 LED INDICATORS 4 REAR PANEL CONNECTORS 4 Twisted pair Jacks 4 Uplink Jack 5 Power Jack 5 INSTALLATION 6 INSTALLING THE HUB 6 CONNECTING THE POWER ADAPTER 6 CABLES AND CONNECTORS 7 CROSSOVER CABLES 8 SPECIFICATIONS 10 GENERAL 10 ENVIRONMENTAL AND PHYSICAL 10 Rev 01 ...

Page 5: ... hubs together The hub features LINK RX LEDs to show the network connection and packet receiving status of each twisted pair port PWR power and COL collision indicators show the operational status of the hub Product Features Compliance with IEEE 802 3 10Base T and 10Base 2 TE 910plus only standard Automatic partitioning function of each port to isolate network failure RJ45 ports support Category 3...

Page 6: ...2 The Front Panel of The Hub 5 port Ethernet Hub 8 port Ethernet Hub 9 port Ethernet Hub with BNC port ...

Page 7: ...3 The Rear Panel of The Hub 5 port Ethernet Hub 8 port Ethernet Hub 9 port Ethernet Hub with BNC port ...

Page 8: ...en when a network connection is established This indicator blinks green when the hub is receiving data packets BNC TE 910plus only This indicator blinks green when BNC port connection has network activities network connection is established on the BNC port Rear Panel Connectors RJ45 MDI X Twisted pair Jacks Use these jacks to connect Ethernet devices server workstation print server to the hub Thes...

Page 9: ...opulated segments Ethernet connection rule Basically you can only uplink 4 hubs together using the UTP cable The maximum CAT3 4 or 5 twisted pair cable distance between two Ethernet devices is 100 meters If you have question about this rule please contact our support department at techsupport trendware com BNC Port TE910plus only To connect the 10Base 2 network attach the thin coax cable s BNC T C...

Page 10: ... direct exposure to sunlight Leave at least 10 cm of space at the front and rear of the hub for ventilation Note not to block the ventilation holes on the top of the hub Install the hub on a sturdy level surface that can support its weight You can stack two or more hubs together by inserting the two small round legs at the bottom of the hub to the two holes on top of another hub Connecting the Pow...

Page 11: ...um segment length 100 meters Connectors RJ 45 Straight Twisted Pair Cable Pinouts Contact MDI X Signal MDI II Signal 1 RD receive TD transmit 2 RD receive TD transmit 3 TD transmit RD receive 4 Not used Not used 5 Not used Not used 6 TD transmit RD receive 7 Not used Not used 8 Not used Not used BNC Cable Thin Coax RG 58U or RG 58A U 50 Ohms cable 185 meters maximum segment length requires 50 Ohms...

Page 12: ...cable 1 Leave one end of the cable as is with the wiring on the RJ 45 connector unchanged The wiring needs to be modified at one end only 2 At the other end of the cable connect wire 1 from the unchanged connector to wire position 2 connect wire 3 to wire position 6 connect wires 3 to wire position 1 and connect wire 1 to wire position 2 Refer to the following diagram If you have question regardin...

Page 13: ......

Page 14: ...STP 8 x STP 8 x STP 1 x BNC Network Media Category 3 or better UTP cable maximum length 100 meters Thin coax RG 58U or RG 58 A U cable maximum185 meters Environmental and Physical Power Adapter Output 7 5VDC 1A Dimensions 176mm 81 5mm 31 3mm TE 910plus 176mm 91 5mm 31 3mm Operating Temperature 0 to 40 C Storage Temperature 20 to 70 C Humidity 5 to 90 non condensing Emissions FCC Class A CE Mark Cl...

Reviews: