your last 5 tested records. 

 

           

 

  The device will be turn off after displaying 20 seconds. 

  The memory button is only used at this mode. 

 

 

Accessories 

  Mouthpieces 

  Manual 

 
 

Errors or Troubles 

 

     

Error message   

or Troubles 

   
                              Description 

 
        Remarks 

 
 
No display 

 
-Press and hold the TEST button until power on. 
-Check the battery   

   

 

 

 

 

Auto Off 

 

-Low battery 
-Over the period of test stage 

 

 

 

         
 
            Err 

 
-Blowing unsteady or interrupt 
-Blowing less than 6 seconds 
-Blowing flow too weak 
-No blow during BLOW mode. 
-Change temperature suddenly 

 
   

   

 

-Low battery indication 
-Need to change new battery 
-Use alkaline battery 

 

   
   

Alarm sound 

 
-During the blowing mode 
-Error message indication 
-Above alcohol set point   

 
   

Summary of Contents for TM-7500

Page 1: ......

Page 2: ...TENTS Introduction 1 Correct Measurement 1 Description of Parts 1 Power Supply 2 Operation 2 Accessories 4 Error and Troubles 4 Important Notes 5 Specifications 5 Calibration and Record 6 Precautions...

Page 3: ...this device has been established at a Blood Alcohol Concentration of 0 008 0 08 and 0 032 0 32 BAC Accuracy at a Blood Alcohol Concentration greater than 0 032 0 32 BAC has not been established Prepa...

Page 4: ...the power is too low the unit may display a battery symbol and the device may not use correctly You need to change a new battery Operation Test mode Insert one of the mouthpieces into the blow in hole...

Page 5: ...e displays WAIT and flashing the 0 on the screen Your test result will be displayed on the screen for 20 seconds It will show error when incorrect blowing Refer to the chapter of the Errors and Troubl...

Page 6: ...s No display Press and hold the TEST button until power on Check the battery Auto Off Low battery Over the period of test stage Err Blowing unsteady or interrupt Blowing less than 6 seconds Blowing fl...

Page 7: ...ons Electron chemical sensor Fuel Cell Sensor Blowing time 6 seconds Blowing flow 10L min Display range 0 000 2 000 BAC Show HI if above the display range Accuracy 0 05 at 0 5 Memory 5 records 5 mouth...

Page 8: ...BAC may change some minutes later You should have your alcohol tester calibrated every 12 months Failure to do so may cause your readings to be inaccurate Do not use this device to determine if you c...

Page 9: ...or used functionally equivalent to the original unit 3 Refund the purchase price of the unit For warranty service please follow these instructions 1 Call or email to obtain an RMA number 2 Return the...

Reviews: