Description

Variable motor speed drives suitable for HVAC applications 

where the speed control of motors can be applied. They 

convert fixed frequency and voltage from the mains supply to 

variable frequency and voltage enabling motors to be used with 

maximum efficiency resulting in significant energy savings. 

The control keypad can be mounted on the front of the unit or 

can be remotely connected by way of a  2 m cable and mounted 

on a panel or used as a handheld unit.

The keypad accesses the startup wizard which facilitates the  

the application configuration for the user (pump/fan, PID loops, 

multi-pump, cascade control).

Features

 

380 to 480 Vac 3 phase

 

▪ current rating range from 3 A to 310 A

 

▪ IP21 and IP54 models available

 

▪ optional Trend system network interfaces (NXNI or NXIP)

 

▪ application configurable using wizard for a number pump or 

fan scenarios 

 

▪ real time clock fitted with battery

 

▪ integrated RFI filter for typical building installation

 

▪ versatile PC tools available

 

▪ slim, space-saving, “bookshelf” design

 

▪ varnished printed circuit boards to maximise reliability

3 A to 105 A

 units (unit size MR4 to MR7) - wall mounting

* For MR8, MR9 detail see next page

Current (A)

A

B

C

D

E

ØF

ØG ØH ØI

Frame

3 to 12

128 328

190

100 313

7

13

25 25

MR4

16 to 31

144

419

214

115

406

7

14 33

25

MR5

38 to 61

195 557 229

148

541 9 15.5

40 33

MR6

72 to 105

237

660

259 190 645 9

16

50 50

MR7

140 to 205 290 966

343

217 947 9

16 60 60

MR8*

261 to 310 480

1150 365

400 1122

9

16

59 59

MR9*

Physical 

(dimensions in mm)

For 

140 to 310 A

 sizes see next page

S= supply cable

M= motor cable

C= control cable

Summary of Contents for VSD2H

Page 1: ...s multi pump cascade control Features 380 to 480 Vac 3 phase current rating range from 3 A to 310 A IP21 and IP54 models available optional Trend system network interfaces NXNI or NXIP application con...

Page 2: ...ving in installation costs switchgear is eliminated motor cables are reduced from 6 to 3 wires for larger drives power factor correction capacitors are not required size and cost of cabling and fuses...

Page 3: ...ctors identified by letters A B D E of the control board When the frequency converter is delivered from the factory the control unit includes the standard complement of two basic boards the Basic I O...

Page 4: ...on 4 AI2 Analogue input voltage or current DIP switch 3 selects V or mA Differential input if not connected to ground PID actual value 1 4 to 20 mA 5 AI2 Analogue input c2 ommon 6 24 Vout 24 V auxilia...

Page 5: ...to be mounted in the panel door connected to the VSD by a 2 m cable RS485 AO1 AI2 AI1 OFF ON Current RS485 fieldbus termination resistor Current Current Voltage Voltage Voltage Default positions are...

Page 6: ...e clock the drive fan keypad settings and fieldbus RS485 or Ethernet parameters User settings Language application parameter backup and restore to and from keypad Favourites advanced commissioning key...

Page 7: ...lso to high inertia loads High Switching Frequency The VSD2H is capable of providing the maximum power with high switching frequency Benefit Low audible noise from the motor Prohibit frequency Overrid...

Page 8: ...ed motor cables is recommended they should be routed as far away from other cables as possible and cross other cables at right angles The motor cable shield should be grounded at both the VSD2H drive...

Page 9: ...lt settings RJ45 USB Note that the NXNI interface connects the drive directly to the an IQ system current loop Lan and the NXIP connects the drive to an IQ system Lan on Ethernet They both enable the...

Page 10: ...Laninterface see NXNI data sheet NXIP NXvariablespeeddriveIQsystemLanonEthernetinterface see NXIP data sheet ACC VSD2H DOOR MOUNTING KIT Kit to mount keypad unit on door includes 2 m cable ACC VSD2H H...

Page 11: ...fications Electrical Supply voltage 380 to 480 Vac 10 3 phase Frequency 50 to 60 Hz 5 10 Connection to mains once per minute or less Starting delay 4 s MR4 to MR6 6 s MR7 to MR9 Motor voltage 0 to sup...

Page 12: ...logue output 1 output AO1 can be set to either voltage or current by DIP switch RL 500 ohm resolution 0 1 accuracy 2 Short circuit protected Voltage 0 2 to 10 V Current 0 4 to 20 mA The lower range 0...

Reviews: