background image

3

IQ3../.../XNC/... Controller/Interface Installation Instructions TG200911 Issue 1/D 03/09/07

Installation Instructions

IQ3../.../XNC/...

Connect IQ System Current Loop Network

3

If /LAN/.., IQ system current loop Lan auxiliary board,
fitted

4    5    6

4    5    6

2

7    8    9

3

10  11  12

4

13  14  15

5

16  17  18

6

19  20  21

7

22  23  24

8

25  26  27

9

28  29  30

10

+           0

+           0

+           0

+           0

+           0

+           0

+           0

+           0

+           0

+           0

+           0

1    2    3

1    2    3

1

+           0

0V

24

V

24

V

34  35  36

12

37  38  39

13

40  41  42

14

A

31  32  33

P

11

43  44  45

15

46  47  48

16

100-240 V

OK       RX

P           0

P           0

P           0

P           0

P           0 P           0

P           0

TX

RX

OK

1 Installation - Mounting 

(continued)

25  26  27

N

+           0

1

2

3

4

1

2

3

4

IQ LAN

IQ LAN

T-

T+

R-

R+

T-

T+

R-

R+

1

2

3

4

1

2

3

4

T-

T+

R-

R+

T-

T+

R-

R+

2 off 2 part connectors with 4 screw terminals for 0.5 to 2.5 mm

2

 cross

section area (14 to 20 AWG) cable

IN

OUT

earth (ground) screen to convenient
input channel screen terminal

Using 2 wire method

25  26  27

N

+           0

1

2

3

4

1

2

3

4

IQ LAN

IQ LAN

T-

T+

R-

R+

T-

T+

R-

R+

1

2

3

4

1

2

3

4

T-

T+

R-

R+

T-

T+

R-

R+

IN

OUT

Using 4 wire method

polarity independent

Continue Installation

4

IQ3xact Installation Instructions TG200766

IQ3xcite Installation Instructions TG200626

Install according to IQ3xact installation instructions section 4 step 1 to step 19,
or IQ3xcite installation instructions from section 3 step 12 to section 4 step 20.

Network Engineering Manual, 92-1735

e

l

b

a

C

d

u

a

b

6

k

9

d

u

a

b

2

k

9

1

s

e

r

i

W

f

o

.

o

N

2

8

1

9

n

e

d

l

e

B

m

0

0

0

1

)

s

d

y

0

9

0

1

(

m

0

0

7

)

s

d

y

5

6

7

(

2

7

0

2

9

n

e

d

l

e

B

m

0

0

0

1

)

s

d

y

0

9

0

1

(

m

0

0

5

)

s

d

y

5

4

5

(

2

d

n

e

r

T

0

0

2

/

F

H

/

2

2

/

1

/

1

/

P

T

)

1

6

7

8

n

e

d

l

e

B

(

m

0

0

7

)

s

d

y

5

6

7

(

m

0

5

3

)

s

d

y

0

8

3

(

2

d

n

e

r

T

0

0

2

/

F

H

/

2

2

/

2

/

2

/

P

T

)

3

2

7

8

n

e

d

l

e

B

(

m

0

0

5

)

s

d

y

5

4

5

(

m

0

5

2

)

s

d

y

0

7

2

(

4

earth (ground) screen
to convenient input
channel screen terminal

Summary of Contents for IQ3 series

Page 1: ...wo RS232 connectors can be used at a time 0V T A T B RA RB 0V A B 0V A B 0V A B 120ohm terminator Terminator switch ON IQ3 SER XNC either RS485 2 wire RS485 4 wire or RS422 2 part connector with 5 scr...

Page 2: ...ple Cabinets If the IQ3 XNC SER controller and its slave units are in different cabinets or use different power supplies e g different UPSs the cabinets should be isolated from each other If the bus i...

Page 3: ...to convenient input channel screen terminal Using 2 wire method 25 26 27 N 0 1 2 3 4 1 2 3 4 IQ LAN IQ LAN T T R R T T R R 1 2 3 4 1 2 3 4 T T R R T T R R IN OUT Using 4 wire method polarity independe...

Page 4: ...4 45 15 46 47 48 46 47 48 16 100 240 V OK RX P 0 P 0 P 0 P 0 P 0 P 0 P 0 P 0 P 0 P 0 P 0 TX RX RTS TXEN CTS RXEN RS485 RS232 terminator in circuit terminator out of circuit RS485 4 wire RS485 2 wire R...

Page 5: ...RX a TX c OK Network Address 0 2 3 or 119 IQ3 LAN XNC O I 1 2 3 4 1 2 3 4 IQ LAN IQ LAN T T R R T T R R 1 2 3 4 1 2 3 4 T T R R T T R R 1 2 3 4 1 2 3 4 IQ LAN IQ LAN T T R R T T R R 1 2 3 4 1 2 3 4 T...

Page 6: ...l interface auxiliary board fitted 4 5 6 4 5 6 2 7 8 9 7 8 9 3 10 11 12 4 13 14 15 5 16 17 18 6 19 20 21 7 22 23 24 8 25 26 27 9 28 29 30 10 0 0 0 0 0 0 0 0 0 1 2 3 1 2 3 1 0 0 0 V 24 V 24 V 34 35 36...

Page 7: ...voltages 417 IEC 5036 Remove Auxiliary Board Cover 4 a b c d CR 2032 CR 2032 Remove battery if replacing battery 5 Replace Auxiliary Board Cover 7 Warning Thelithiumbatterymustnotberecharged disassem...