background image

DIGITAL ANGLE RULE REF. DAR/200

Thank you for purchasing this Trend product which should give lasting performance if used 
in accordance with these instructions.  

INTENDED USE

This accessory is intended to be used to measure the angle and length of a component.

SAFETY 

Read and understand the instruction sheet carefully before using.  This is 
a sensitive precision tool.  Do not disassemble or drop it.  Please note the 
sharp edges, avoid scratching.  Store out of reach of children.  Do not use as 
a toy or as a weapon.
PLEASE KEEP THESE INSTRUCTIONS IN A SAFE PLACE.

7

32NDS

MM

MM
10

20

30

40

50

60

70

80

90

100

110

120

130

140

6

5

4

3

3

2

1

4

5

6

7

2

MM10

220

230

240

250

260

270

280

290300

310

320

330

340

350

360

370

380

390

35mm

Hanging

holes

Locking knob

Battery container

Ruler

LCD

200mm

2.5mm

8mm

200mm

20mm

130 140

2

ZER

O   ON OFF

Tighten

Loosen

130 140

2

ZER

O   ON OFF

Push

Negative

pole

uppermost

130 140

2

ZER

O   ON OFF

Pull

130 140

2

ZER

O   ON OFF

Push

ZER

O   ON OFF

ON/OFF button

ZERO button

1.

 

Short press ON/OFF to turn on, 

close up both rulers and place on the flat 
surface, make sure both ruler’s edges 
touch the surface, press ZERO button 
to set zero.

PP 

C/DAR/200 

v1.0

MM

3

2

1

4

5

6

7

MM 10 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390

7

32NDS

MM 10 20 30 40 50 60

70 80 90 100 110 120 130 140

6

5

4

3

2

MM
10

7”

400mm

Metric Scale (standard rule)

Imperial Scale

7”

MM

3

2

1

4

5

6

7

MM 10 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390

7

MM 10 20 30 40 50 60

70 80 90 100 110 120 130 140

6

5

4

3

2

MM
10

7

MM

MM
10

20

30

40

50

60

70

80

90

100

110

120

130

140

6

5

4

3

3

2

1

4

5

6

7

2

MM10

220

230

240

250

260

270

280

290300

310

320

330

340

350

360

370

380

390

7

MM 10 20 30 40 50 60

70 80 90 100 110 120 130 140

6

5

4

3

2

MM
10

7

MM 10 20 30 40 50 60

70 80 90 100 110 120 130 140

6

5

4

3

2

MM
10

MM

3

2

1

4

5

6

7

MM

10

220

230

240

25

0

260

270

280

290

300

31

0

320

330

340

350

36

0

37

0

380

390

7

MM 10 20 30 40 50 60

70 80 90 100 110 120 130 140

6

5

4

3

2

MM
10

MM

3

2

1

4

5

6

7

MM

10

220

230

240

25

0

260

270

280

290

300

31

0

320

330

340

350

36

0

37

0

380

390

2.

 

Rotate the rule to measure the angle.

Li-lon

Battery Fitting and 

Replacement

To fit or replace battery push the tab on 
the bottom of the LCD.   
The edge of the battery container will 
appear on the opposite side of the LCD.

Pull the battery container out.

Remove the old battery. Insert the new 
battery type CR2032 3v.

Ensure the negative pole of the battery 
is uppermost.  The positive pole is on 
the underside of the battery.

Push the battery container back in.

Denotes risk of personal injury, loss of life or damage to the tool in case of 
nonobservance of the instructions.

The attention of UK users is drawn to The Provision and Use of Work Equipment 
Regulations 1998, and any subsequent amendments.  Users should also read 
the HSE/HSC Safe Use of Woodworking Machinery Approved Code of Practice 
and Guidance Document and any amendments.  Users must be competent in 
woodworking equipment before using our products.

n

  Rotate clockwise to tighten  

 

the moving rule.  

n

  Rotate anti-clockwise to    

 

loosen the moving rule.

TROUBLE SHOOTING

Problem  

Possible Cause 

Solution

No display or 

Lower voltage, no battery or  

Reinstall battery or

ambiguous reading. 

incorrect installation of battery. 

replace battery. 

Erratic display. 

Misfunction caused 

Press zero to reset

 

by high vibration or heavy 

zero.

 

swinging of rule.

Number skip or 

Internal error. 

Remove battery, wait one

frozen display. 

 

minute and replace.

MAINTENANCE

The rule has been designed to operate for a long period of time with the minimum of 
maintenance.  Continual satisfactory operation depends upon proper tool care and regular 
cleaning.

Cleaning

n

  Clean with mild liquid soap and damp cloth.  Dry with soft cloth.  Never immerse in  

 

water.  Rule requires no additional lubrication.

Storage

n

  Return to packaging after use if it is not to be used for a long time.  Store rule in a dry  

 

and shady place.  Never leave it outside or in a wet environment.  Before storing, it is  

 

recommended to wipe surfaces with an anti-rust oil.

GUARANTEE

All Trend products are guaranteed against any defects in either workmanship or  
material, except products that have been damaged due to improper use or maintenance. 

ENVIRONMENTAL PROTECTION

Recycle raw materials instead of disposing as waste.  Packaging should be sorted for 
environmental-friendly recycling.  The product, at the end of it’s life, should be sorted for 
environmental-friendly recycling.

Batteries and the Environment

  

This unit uses Lithium Ion (Li-Ion) batteries.  When battery pack needs replacing,  

 

we recommend the following: Discharge the energy from the batteries by running  

 

them down completely and then remove from the tool.  

Li-Ion cells are recyclable so do not throw them away with household waste.  They may 
end up in an incinerator or landfill, which must be avoided.  
Instead, take the batteries to a Trend Service Agent, your local Trend Stockist or a local 
recycling station.  If necessary contact your local municipality for disposal information.   
The collected batteries will be disposed of properly and/or used for recycling purposes.

DESCRIPTION OF PARTS

Battery Care

 

WARNING! 

Insert battery correctly.  Keep batteries away from children.  Do

not swallow, open, recharge, or expose to water, fire or high temperature: may explode, 
leak and cause damage.

 

CONFORMITY 

 

DECLARATION

This product conforms with EMC Directive 2004/108/EC.

TECHNICAL DATA

Measuring Range:  000.0° - 999.9°  (more than 999.9° will show incorrect display)
Working Temperature:  0°C to +50°C     Working Humidity:     85% RH
Working Current:     50 uA     Resolution:  0.1°     Accuracy:  0.3°
Battery:  CR2032 3V Lithium Battery     Weight:  162g

Measuring Obtuse 

Angles

2.

 

Rotate the rule to measure the angle.

1.

 

Short press ON/OFF to turn on, 

open up both rulers and place on the flat 
surface, make sure both ruler’s edges 
touch the surface, press ZERO button 
to set zero.

135º

45º

ON/OFF 

button: Short press ON/OFF to turn 

on, or alternatively move the scale to turn 
on the device when at off LCD status.  Short 
press ON/OFF to turn off the LCD.  Long 
press ON/OFF for more than 3 seconds to 

shut off the whole system.  Automatically turns 
off in 6 minutes.  

ZERO 

button: Press ZERO to set zero at any 

point when turned on.

OPERATION

Measuring Acute 

Angles