background image

AIRSHIELD

-8-

AIRSHIELD SAFETY
PRECAUTIONS

Control Of Substances Hazardous to Health
(COSHH) recommend that Respiratory
Protective Equipment should be stored in a
cool dry place.

For adequate protection the Airshield must fit
or be adjusted to the size of the head.

DO NOT clean with proprietary cleaning
media or solvents, follow the instruction in
manual. 

DO NOT apply paint, solvents, adhesives or
self-adhesive labels which are not approved
by Trend.

DO NOT use Airshield without pre-filter and
main filter fitted, with damaged seals and/or
damaged visor.

DO NOT use replacement parts except those
supplied by Trend Machinery & Cutting Tools
Ltd.

To maintain the full efficiency of the Airshield,
there must be no alteration to the structure or
its component parts.

When using two battery packs always fit two
fully charged replacements.

Toxic Dusts on the respirator or filters from
usage should be handled in a safe manner in
accordance with your chemical or material
suppliers instructions.  Used filters to be
disposed of safely in the same manner.

If further information is required with regard to
Airshield, please contact Trend Machinery &
Cutting Tools Ltd.

BEFORE USE

Charge the battery pack/packs before use.
Ensure the respirator is correctly assembled with
pre-filter, main filter and either one or two fully
charged battery packs fitted.

Battery Pack Charging

Battery pack must be initially charged
for 24 hours.

The Powered Respirator is supplied with one
rechargeable battery pack for four hours duration.

For eight hours duration an additional rechargeable
battery pack and battery charger is required.

Check that the voltage shown on the charger is
suitable for the mains supply.  A thermal fuse
protects the charger against short circuiting and
overloading.

Push the battery pack connector into the charger
socket and plug the charger into the AC supply
socket.  The light on the charger confirms that the
battery pack is charging.

Battery packs should be initially charged for 24
hours and 14 hours thereafter when fully
discharged.  A 3.5 hour charge will enable 1 hour of
usage.  Full working capacity of the battery will not
be achieved until the battery has been through 3 or
4 complete charging cycles.  Please note the light
will not extinguish when a full charge has been
achieved.

The charger must be 
disconnected from the mains supply
when not in use.

After the charging period, withdraw the charger
from the AC supply socket and disconnect the
battery pack from the charger.

IMPORTANT!

IMPORTANT!

MANU-AIR v5.0  16/5/05  11:24 am  Page 8

Summary of Contents for AIRSHIELD

Page 1: ...AIRSHIELD RESPIRATOR APPROVED TO EN146 1991 VISOR APPROVED TO EN166 1995 MANU AIR v5 0 16 5 05 11 24 am Page 19...

Page 2: ...s risk of personal injury loss of life or damage to the tool in case of non observance of the instructions in this manual INTENDED USE The Airshield is a lightweight Powered Respirator intended for pr...

Page 3: ...d European Standard Number Number 3 is protection against droplets and splashes or liquids Number 4 is protection against large dust particles Letter F is the symbol for resistance to high speed parti...

Page 4: ...temp 0 45 atmospheric pressure 800 1300 mbar humidity 0 90 TECHNICAL SPECIFICATION Type Respirator powered particle filtering device Respiratory Approvals Europe Complies with European Standard BS EN...

Page 5: ...flow Indicator Carry Bag Knob Switch Ratchet ITEMS ENCLOSED 1x Airshield complete 1x Airflow Indicator 1x 4 Hour Rechargeable Battery 1x Disposable Visor Overlay Clear may be already fitted 1x Battery...

Page 6: ...AIRSHIELD 5 15 12 11 13 5 8 6 7 16 14 1 3 2 9 10 4 MANU AIR v5 0 16 5 05 11 24 am Page 5...

Page 7: ...handles dry clean and free from oil and grease Maintain accessories Do not use damaged accessories Only use accessories recommended by the manufacturer Check damaged parts Before operation inspect the...

Page 8: ...on and damage the shank and should be replaced Worn collet nuts should be replaced Do not take deep cuts in one pass take several shallow or light passes to reduce the side load applied to the cutter...

Page 9: ...ge the battery pack packs before use Ensure the respirator is correctly assembled with pre filter main filter and either one or two fully charged battery packs fitted Battery Pack Charging Battery pac...

Page 10: ...ratchet knob anti clockwise to enlarge the headband and lift the visor towards the back of the headband Fit the Airshield onto the head by entering the head into the headband Switch the fan motor uni...

Page 11: ...at above until a correct fit is achieved Ensure that the unit is pivoted down fully so that the headband stops are against the main fan housing The plastic headband lugs are designed to limit the move...

Page 12: ...n and cement may suit more frequent replacement of pre filter to extend the life of the main filter No filter should be left in the hood helmet for more than 1 month if in daily use or 3 months if use...

Page 13: ...supplied by Trend Machinery Cutting Tools Ltd will not be guaranteed and invalidate such National approvals as held by Trend Machinery Cutting Tools Ltd Modifications to the Airshield will make the ap...

Page 14: ...ards to engage the lugs into the holes Ensure the lugs are fully engaged in the holes Carry out a functional test as described previously Face Seal Pull the face seal away from the hook fastener strip...

Page 15: ...ss down adhesive strips and remove protective paper 2 3 4 1 Headband Pull apart to separate hook fasteners to remove the sweatband from the headband Detach each end of the face seal from the headband...

Page 16: ...efully press the sides of the visor and lift it from the visor frame Flex replacement visor and insert the top and sides into the visor frame ensuring that the top visor tabs slide outside of the fram...

Page 17: ...and the environment This unit uses Nickel Metal Hydride Ni MH batteries When the battery pack needs replacing we recommend the following Discharge the energy from the batteries by running the batteri...

Page 18: ...AIRSHIELD IB AIRSHIELD SPARE PARTS DIAGRAM v4 0 05 2002 2 16 3 5 4 9 11 13 13 14 8 12 17 11 14 1 19 20 18 7 12 6 22 21 MANU AIR v5 0 16 5 05 11 24 am Page 17...

Page 19: ...ot be held liable for any material rendered unusable or any form of consequential loss E OE All trademarks acknowledged RECYCLABLE Trend Machinery Cutting Tools Ltd Odhams Trading Estate St Albans Roa...

Reviews: