TCG250 Floor Grinder
Checking chart
Before Operation
After Operation
Monthly
Every 3 Months
Every Year
If Damaged/Worn
Complete Machine
Check
X
Clean
X
Pulleys & Belt
Check (Damage & Tension)
X
X
Tension
X
Replace
X
X
Vacuum Ports
& Accesories
Check
X
Clean
X
Replace
X
X
Dust Seals
Check
X
Clean
X
Replace
X
X
Grinding Tools &
Accesories
Check
X
Clean
X
Replace
X
Bearings & Seals
Check
X
X
Replace
X
X
Height Adjusting
Rod &
Connections
Check
X
Lubricate
X
Replace
X
Honda Engine
Check Fuel Level
X
Check Oil Level
X
Operational Check (No Load)
X
Review Manufacturer’s Manual
X
Pneumatic Engine
Check Lubricant Oil Level
X
Operational Check (No Load)
X
Review Manufacturer’s Manual
X
Electrical Motors
Visual Inspection
X
Clean Air Passages
X
Operational Check (No Load)
X
X
Based on normal & safe operating procedures and hours