Trelawny A70 Operation And Maintenance Manual Download Page 4

OPERATION

 

Foreword

 

Thank  you  for  your  purchase  of  the 

TRELAWNY  Professional  use  A70 

Industrial Vacuum Cleaner. 

 

 

This manual  contains  the  necessary 

maintenance  information  for  you  to 

ensure proper operation and care for 

this machine.

 

 

It  is  essential  for  you  to  read 

through this manuals thoroughly.

 

 

In  the  unlikely  event  that  you 

experience  problems  with  your  A70 

Vacuum,  please  do  not  hesitate  to 

contact your local Trelawny dealer or 

agent. 

We 

always 

welcome 

feedback  and  comments  from  our 

valued customers.

 

 

 

General Information

 

Before 

operating, 

performing 

maintenance  or  repairing  the  A70 

Industrial  Vacuum  Cleaner,  this 

manual 

must 

be 

read 

and 

understood by the operator, if in any 

doubt,  ask  your  supervisor  before 

using this equipment.

 

 

Local  safety  regulations  must  be 

followed at all times. Failure to follow 

these  instructions  could  result  in 

damage  to  the  A70  Vacuum  and/or 

personal injury. 

 

 

Trelawny  SPT  Limited  disclaims  all 

responsibility for damage to persons 

or objects arising as a consequence 

of incorrect handling of the machine, 

failure  to  inspect  the  machine  for 

damage  or  other  faults  that  may 

influence  the  operation  prior  to 

starting  work,  or failure  to  follow  the 

safety regulations listed or applicable 

to the job site.

 

This  machine  is  primarily  designed 

for the containment of nuisance dust 

and dust collection.

 

 

HEPA  filtered  vacuum  system  is 

available,  which  will  contain  99.97% 

(DOP)  of  all  air  borne  dust  when 

removing  toxic  or  contaminated 

products.

 

 

 It  can  be  used  both  indoors  and 

outside in dry weather only.

 

This  machine  is  not  water  proof, 

avoid splashing with water if using to 

collect fluid spills.

 

Safety

 

The person in charge of safety shall 

be responsible for informing workers 

about  the  risks  associated  with 

vacuum cleaner operations.

 

 

Train  operators  in  the  correct  use 

and  maintenance  of  the  vacuum  in 

order  to  protect  themselves  and 

others from hazards.

 

 

Failure  to  observe  basic  safety 

regulations  and  precautions  could 

cause  accidents  during  the  vacuum 

cleaners  operation,  maintenance  or 

repair. 

 

 

Trelawny 

shall 

under 

no 

circumstances  be  deemed  liable  for 

accidents or damage caused by use 

of  the  vacuum  cleaner  by  personnel 

not  properly  trained  or  who  use  it  in 

an improper manner.

 

 

The  safety  precautions  and  warning 

notices  are  indicated  in  this  manual 

and on the product.

 

 

Unless  these  hazard  messages  are 

heeded,  the  operator  could  become 

involved  in  accidents  with  serious 

consequences  for  him/herself  and 

others.

 

 

Trelawny cannot foresee all possible 

circumstances 

capable 

of 

representing  a  potential  hazard, 

therefore the warnings in this manual 

and  on  the  product  should  not  be 

deemed exhaustive.

 

 

 

Only  ever  use  original  Trelawny 

spare parts

 

 

Trelawny  declines  all  liability  in 

the  event  of  non

-

original  spare 

parts being used.

 

 

In  the  event  of  tools,  procedures  or 

work  methods  used  that  are  not 

explicitly recommended by Trelawny, 

ensure  no  hazards  exist  for  the 

operators and others.

 

 

 

 

 

 

Further  advice  is  available  from  our 

Technical Department.

 

The  employer  must  inform  and  train 

the  user  according  to  the  provisions 

of applicable local laws.

 

 

Before  using  the  machine,  prepare 

and  train  yourself  by  reading  this 

manual carefully.

 

 

Use of the machine by untrained and 

unauthorised persons is forbidden.

 

 

Do  not  use  the  machine  to  vacuum 

toxic  substances  unless  it  has  been 

equipped  with  the  special  filters 

required for the specific type of dust. 

 

 

Such  filters  must  be  explicitly 

requested by you.

 

 

Do  not 

vacuum flammable materials 

or  substances  or  which  could  cause 

explosions  (fuels,  solvents,  etc.).  To 

vacuum such materials, the machine 

must  be  built  with  anti

-

explosion 

motor  and  electric  system  and  this 

must be requested by you explicitly.

 

 

Do not vacuum corrosive substances 

unless the machine is equipped with 

containers  suitable  for  this  purpose 

(Stainless

-

Steel AISI 304).

 

 

Use  of  the  machine  without  the 

supplied filters is not recommended.

 

 

If  the  machine  is  used  to  vacuum 

toxic/harmful 

substances, 

the 

container  must  be  emptied  and  the 

filters  cleaned  using  adequate 

P

ersonal 

P

rotection 

E

quipment.

 

 

This 

machines 

motor 

casing 

contains 

electrical 

components 

which must not be dismantled by the 

user.

 

 

When  using  the  machine,  be  aware 

of other people around you.

 

 

Use  the  machine  cautiously  on 

slopes  and  ramps.  Do  not  change 

direction on gradients. 

 

 

Make  sure  the  parked  machine 

remains  stable  by  operating  the 

braked wheel.

 

 

Do  not  open  the  vacuum  container 

with the motor running.

 

 

Summary of Contents for A70

Page 1: ...A70 Industrial Dust Collector manual version ENDLESSBAG Operation and Maintenance Manual www trelawnyspt co uk ...

Page 2: ......

Page 3: ......

Page 4: ...amage caused by use of the vacuum cleaner by personnel not properly trained or who use it in an improper manner The safety precautions and warning notices are indicated in this manual and on the product Unless these hazard messages are heeded the operator could become involved in accidents with serious consequences for him herself and others Trelawny cannot foresee all possible circumstances capab...

Page 5: ...always quote the details shown on the vacuum cleaner serial plate To change the filter switch off the vacuum cleaner and remove the plug from the power socket release and remove the upper cap and then loosen nut A HEPA Filter Cartridge Class H 303 5274 Operation Warning The vacuum is heavy but it will move easily on flat ground If moving on any inclined ground take extreme care that control is not...

Page 6: ...compliance with EC standards and with cable cross section suitable for the power input of the vacuum cleaner Lock the front castor wheel 7 Grip one end of the flexible hose complete with selected accessory To start switch on the motor and start vacuuming To stop the vacuum cleaner return the switch to the off position Dispose the contents of the ENDLESSBAG into a special waste disposal container i...

Page 7: ...maintenance job the maintenance engineer must Disconnect the plug from the power socket Work done on motors or other electrical component parts must only be performed by a specifically trained electrician authorised by the Safety Manager Always use tools that are in perfect condition and specifically made for the operation to be done The use of unsuitable tools or tools not in good condition could...

Page 8: ... the cap back on The container locking operation must be performed by one person only who must lower the lever with both hands to lock the canister in position Replacing the filters To replace the filters proceed as follows Turn off the vacuum cleaner by pressing down the motor STOP switches Disconnect the vacuum cleaner plug from the power socket Ensure front wheels are locked Lift the lever that...

Page 9: ...agnetic switch tripped Reset the thermal magnetic switch Loose wiring incorrect voltage or blown fuse Check connections and power supply or replace fuse Dust is leaking out Perforated vacuum pipe Replace the pipe Perforated filter Replace the filter Filter unsuitable for type of job Fit a suitable filter for the type of material to be vacuumed The vacuum cleaner does not work as it should Pipe per...

Page 10: ...EW MACHINE Item Part No Description 1 Machine Body Kit 2 303 5389 HEPA Filter Kit 3 303 5271 20 Pocket C Polyester Filter 4 303 5388 Chamber Kit HEPA 303 5384 Chamber Kit Non HEPA 5 303 5399 ENDLESSBAG Hopper Kit ...

Page 11: ...EXPLODED VIEW FILTER UNIT Item Part No Description 1 303 5304 Adhesive Gasket 2 303 5617 Spacer Ring 3 303 5274 HEPA Filter 4 303 5586 Grommet 5 303 5415 Plain Washer 6 303 5424 M8 x 150 Hexagon Bolt ...

Page 12: ... Part No Description 1 303 5289 Filter Gasket 2 303 5507 Filter Holder Ring 3 303 5493 Filter Clamp 4 303 5544 Filter Cage 5 303 5271 20 Pocket C Polyester Filter 6 303 5502 Filter Shaker Cage 7 303 5581 R Clip 8 303 5503 Clevis Pin ...

Page 13: ...Bracket 4 303 4588 Handle 5 303 5360 Gasket 6 303 5489 Filter Shaker Flange 7 303 5488 Filter Shaker Lever 8 303 5492 Filter Shaker Lever Bellows 9 303 5491 Filter Shaker Lever Knob 10 303 5500 Deflector 11 303 5302 Inlet Gasket 12 303 5499 Inlet 13 303 5508 Latch Pin 14 303 5506 Connector Latch 15 303 5504 Spring 16 303 5306 Adhesive Gasket 17 303 5562 R H Mounting Bracket ...

Page 14: ...Description 1 303 5627 ENDLESSBAG Hopper 2 303 5347 O Ring 3 303 5355 Flap Gasket 4 303 5604 Flap 5 303 5584 Spring 6 303 5603 Flap Arm 7 303 5583 Container ENDLESSBAG 8 303 5602 Knob 9 303 5605 ENDLESSBAG Container Hanger 10 303 5770 ENDLESSBAG ...

Page 15: ...EXPLODED VIEW MOTOR HEAD COMPONENTS ...

Page 16: ...valve 34 303 5155 Vacuum Gauge 10 303 5780 Pressure Relief Valve 35 303 5212 Straight Connector Push in fit 11 303 5215 Nylon Pipe 36 303 5201 Nut 12 303 5160 Swivel Elbow Push in fitting 37 303 5216 Cable Fastener 13 303 5536 Flange 38 303 5559 Upper Cover Plate 14 303 5298 Flange Gasket 39 303 5303 Gasket 15 303 5257 Suction Unit 40 303 5564 Push Handle 16 303 5563 Suction Unit Spacer 41 303 555...

Page 17: ... appreciated All rights reserved Any unauthorised use or copying of the contents or part thereof is prohibited This applies to trademarks model denominations part numbers and drawings Use only genuine Trelawny spares The use of non Trelawny spare parts invalidates the warranty Model 230 400v Power Watts 5 5kW Vacuum rate Mm H2O 2300 Max Air flow M3 h 500 Noise level dB A 76 Filter type material Po...

Page 18: ...NOTES ...

Page 19: ...NOTES ...

Page 20: ...own Road Sydenham Industrial Estate Leamington Spa Warwickshire CV31 1XT United Kingdom Telephone 44 0 1926 883781 Fax 44 0 1926 450352 Email sales trelawny co uk TSPT UK 2017 Part No 735 6060 issue 3 6 17 www trelawnyspt co uk ...

Reviews: