DESCRIPTION OF PARTS
Automatic cleaning - It takes place automatically every 350 hours of
operation of the recirculation pump.
If the filter is clogged, the system automatically activates a cleaning
cycle.
If the problem persists, the system locks all of the functions and the
display shows the message "FL".
In that case, you will have to turn off and on again, after about 30
seconds, the power switch of the product.
The cleaning cycle can be interrupted only by cutting off power to the
product.
Manual cleaning - By pressing the
HYDROMASSAGE
key for
10seconds you will activate the function manually.
There is no limit to the number of cycles that can be performed.
Heater
The heater turns on automatically when the temperature of the water in the spa is one degree below the
value set on the control panel.
The recirculation pump is activated automatically, if not active.
Ozonator
The ozonator is activated by the recirculation pump and turns off automatically when the function
HYDROMASSAGE is enabled.
When the ozonator is running, the LED is active.
Alarms
Alarm temperature
- If the temperature of the water in the spa exceeds 42 °C, all functions are turned
off, the display shows the message "HI" alternating with the value of the temperature.
The alarm and the system automatically resets when the temperature drops below 40 °C.
Alarm temperature prob
e - The probe measures the temperature of the water in the spa and
maintains it steady.
The value of the temperature ranges from 5 °C to 45 °C; outside this range, the system is locked and
the display shows the message "Er".
In this case, you must power off and on again, after about 30 seconds, the power switch of the product.
The message "Er" may also indicate the failure of the temperature probe.
No-flow alarm
- The flow alarm serves to protect the heater and the recirculation pump.
There are two types of alarms: no flow and flow probe failure.
If there is no flow, the heater is switched off, the recirculation pump remains active and the display
shows the message "FL" alternating with temperature.
The alarm and the system automatically resets when the normal operating condition is restored.
The message "FL" may also indicate the failure of the temperature probe.
10sec.
CONTROL PANEL