Key P1:

Key P2:

With the power source connected and water level in the tub (5 cm above the level of the nozzles),

pressing this button activates the 

Whirlpool

function, the backlight of the icon switches from 

dimmed white to bright white. If you want to turn off the feature, press the key again or after 

20 minutes of operation.

By pressing the key without having the proper water level in the tub, the function will not be 

activated and the icon will start flashing with the LEDs indicating the water level 

S2

, flashing, too.

* If the system features a temperature regulator, key P1 controls its activation and deactivation, in 

relation to the tub, according to the following specifications: ACTIVATION: after holding active the 

pump tub for at least 15 sec.

POWER OFF: immediately after pressing the P1 button, which will keep on blinking with the hot tub 

still active for 30 seconds (to allow the cooling of the temperature regulator).

Disinfection can be done only when all functions are disabled and the sensor detects the 

presence of water in the tub.

To carry out disinfection, follow the steps below:
1) press the 

P2

button for 4 seconds > the icon will flash together with key

P1

;

2) confirm the operation by pressing the 

P2

key once again, within 5 seconds: to confirm within 

this limit, the function will abort and the panel will return to its normal state.
During the disinfection phase, the backlighting system of all icons is flashing. No other operations 

can be performed during disinfection, which will end automatically after 10 minutes. If the water 

level is low during disinfection, the function will end.

When the tub is empty and the disinfection completed, the said state of the display will turn off 

after 2 min from the end of operations, for safety reasons ( 2 min safety).

CAUTION: during the disinfection, there should be no people in the tub.

For details on how to fill the disinfection tank, please see page below.

Key P3:

Keys P4:

P4

a

P4

b

With power and water level not necessarily present, pressing this button activates the 

Airpool

function, the backlight of the icon changes from dimmed white to bright white. If you want to turn 

off the feature, press the key again or it will turn off automatically after 20 minutes of operation.

The Airpool function starts by default at maximum speed; to make adjustments press the 

keys 

P4b

and 

P4b

(below).

With 

Airpool

function and the adjustment mode enabled, to vary the speed of the 

blower you must press the keys 

P4a 

and 

P4b

.

The key 

P4a

is disabled and its backlight is off if the blower speed is equal to the minimum 

value, and, conversely, 

P4b

is disabled and its backlight is off if the blower speed is equal to the 

maximum value.

There are 5 speed adjustment steps.

You can exit the setting mode by pressing the button 

P3

or waiting for a few seconds.

_RADIO REMOTE CONTROL - HOW TO USE

Summary of Contents for ATC System

Page 1: ...2019 ATC System HYDROMASSAGE TUBS Instructions for use...

Page 2: ......

Page 3: ...ld like to remind you that all our products are built with top quality materials and are carefully tested according to safety standards This guarantee of quality and comfort is accompanied by strong i...

Page 4: ..._INDEX 4 FOREWORD 4 PRODUCT OVERVIEW 7 PRELIMINARY OPERATIONS 8 GENERAL OPERATION 9 RADIO REMOTE CONTROL HOW TO USE 10 DISINFECTION 13 CLEANING AND MAINTENANCE 14...

Page 5: ...Do not place any electrical devices such as hair dryers lights radios telephones or TV sets at a distance of less than 1 5 m from the tub Don t jump in the tub risk of severe injury and damage to the...

Page 6: ...ed after having disconnected the power supply of the building Wiring must be performed in a fixed and permanent manner without any intermediate connections in accordance with the regulations in force...

Page 7: ...the tub RADIO REMOTE CONTROL CHARGING STATION Function key ON OFF Whirlpool DISINFECTION combined Warning icons Temperature regulator Warning icons Water level low Hidden key ON OFF Blocked Keys Airpo...

Page 8: ...lit and active the following 2 situations may occur a If the RECEIVER is powered tub plugged in the controller will automatically indicate the presence of the signal in a period of about 30 sec and wi...

Page 9: ...key shortly upon release The function warning icons are backlit in two colours according to the following criteria Dimmed white icon function available non active Intense white icon function active B...

Page 10: ...l will return to its normal state During the disinfection phase the backlighting system of all icons is flashing No other operations can be performed during disinfection which will end automatically a...

Page 11: ...e specifications below The colour range consists of 8 colours from white to purple which light up cyclically A complete cycle lasts 2 minutes 15 seconds for each colour To switch the function off pres...

Page 12: ...on _ off if deactivated The S2 signal icon displays the status of the water level set by default to about 5 cm above the level of the nozzles according to the following criteria _ blinking blue if no...

Page 13: ...ub or after prolonged periods of inactivity of the same _DISINFECTION DISINFECTANT On the tub there is the cap of the tank for disinfection The cap can be opened by push pull allowing you to fill itg...

Page 14: ...ale product Their alkaline composition may damage the surfaces Carry out the maintenance of your tub on a regular basis this will maintain the surfaces and the functional parts of the same in optimal...

Page 15: ...NOTES...

Page 16: ......

Reviews: