background image

Rev 1, 11.15.2018 

 

Introduction 

What you should know about these Operating Instructions: 

 

Tree® Professional Weighing Equipment products are simple to operate. 

Nevertheless, you should read through these operating instructions in their entirety, so 
that you can make optimum use of the full potential and the diverse possibilities of the 
weighing machine in your daily work. 
 
These operating instructions contain guidance in the form of pictograms and keyboard 
diagrams, which should help you in finding the required information: 
 
For the labeling of potential hazards, please refer to the Safety proportion of this 
operation manual.  

 

Safety 

 

 Representations & Symbols 

 

Important instructions, which involve safety, are highlighted with the appropriate mark: 
 

 

 
 Safety recommendations 
 
When using the weighing equipment in surroundings with increased safety 
requirements, the corresponding regulations must be observed. 

 
The weighing scale may only be used with the power adapter supplied. 

Before connecting the power adapter to the scale, the user must ensure that the 
operating voltage stated on the power adapter is compliant with the mains voltage. 
If not, please contact Customer Service at the address above. 
 
If the power adapter or its cable is damaged, the weighing scale must immediately be 
disconnected from the electricity supply (pull out the power adapter).  
 

Summary of Contents for MRC2000

Page 1: ...Professional Weighing Equipment Race Car Scales Wireless Car Scale Set Operation Manual ...

Page 2: ...ice 4 Introduction 4 Safety 5 IP65 Protection 6 Weight Scale 7 Functions 8 Features 9 Application Installation 9 10 Getting Started 11 Delivery 11 Assembly Installation 12 Application Menu 13 Program Options 14 16 Calibration 16 17 Maintenance Service 17 Transportation Storage 17 Warranty 18 ...

Page 3: ...oduct to which this declaration refers conforms to the following standards Electronic scale Weigh Bar series Mark applied EU Directive Standards 2004 108 EC EN 61326 1 2006 Signature Boon Lim R D Manager Date 14 09 2018 LW Measurements LLC 620 Carlson Court Rohnert Park CA 94928 Imperial version Metric version MRC2000 MRC 6500 ...

Page 4: ...4 Rev 1 11 15 2018 Customer Service USA LW Measurements LLC 620 Carlson Court Rohnert Park CA 94928 USA Tel 707 542 2185 FAX 707 542 3285 http lwmeasurements com ...

Page 5: ...efer to the Safety proportion of this operation manual Safety Representations Symbols Important instructions which involve safety are highlighted with the appropriate mark Safety recommendations When using the weighing equipment in surroundings with increased safety requirements the corresponding regulations must be observed The weighing scale may only be used with the power adapter supplied Befor...

Page 6: ...e must not be operated in an area subject to explosion risks Care must be taken when weighing liquids to ensure that no liquid is spilled into the inside of the scale or into connections on the rear of the equipment or the power adapter If liquid is spilled on the scale it must immediately be unplugged from the main electricity supply pull out power adapter The weighing scale may be operated after...

Page 7: ...7 Rev 1 11 15 2018 Weight Scale Construction Functions The weighing scale consists of the following parts Digital indicator 1 Scale pads 4 The adapter 1 Operation manual ...

Page 8: ...ghing Platform Size MRC 2000 4 X 550 lb 0 2 lb 12 x 12 6 inches 31 x 32 cm MRC 6500 4X1650 lb 1 lb 35 cm x 40 cm 14 inch x 16 inch Net gross weight 22 kg 25 kg 44lg 55lb 31 5 kg 35 8 kg 69 3 lb 89 5 lb Package Standard carton 67x39 5x40 cm3 26 4x15 6x15 7 inch 64 50x50 5x43 cm 25 4x19 9x16 9 inch Operating Temp 0 40 32 104 Power source 6 V 4AH not included or AC DC Adapter 12V DC 1000mA ...

Page 9: ... weighing of solid materials and of liquids filled into secure containers The maximum capacity load of the weighing scale must never be exceeded otherwise the weighing scale may be damaged In using the weighing scale in combination with other devices as well as with devices produced by other manufacturers the appropriate regulations for the safe use of the relevant attachments and their applicatio...

Page 10: ...ed below when unpacking the scale Unpack the scale carefully When outside temperatures are very low the scale should be stored for a couple hours and kept in its box in a dry room at normal temperature so that no condensation settles on the unit when opening the box Check the scale immediately after unpacking for any external visual damage If there is any damage on scale contact customer service i...

Page 11: ...s placed is very important in order for the scale to work to its full potential Certain conditions can affect the capabilities of the scale conditions like the presence of air flow variations in temperature and direct sunlight Please follow the recommendations given below in choosing a location to place your scale Place the scale on a solid firm and preferably vibration proof horizontal base Make ...

Page 12: ...12 Rev 1 11 15 2018 Application Menu Display overview ...

Page 13: ...ey then turn on the scale the display will show A ON or A OFF press UNIT key twice the display will show P Con or P PC press ZERO key to select Con or PC P Con send data continuously P PC order send host sends 0A HEX order scale will send below data Port setting 9600 N 8 1 Port s data format 48 Bytes Byte 1 3 4 8 9 10 11 12 MODE DATA UNIT CR LF 1 3 MODE FL front left weight MODE RL front right wei...

Page 14: ... Exceed zero track range when power is on Err S Unstable when power is on Err C Calibration code is not enough or operation error Lo Scale Low battery indication Link it means that the Bluetooth connection failed Lob indicator Low battery indication 10 Two calibration weight units kg lb 11 Open calibration capacity 12 Power on zero setting range 10 13 Bluetooth indicator 14 Three modes J ON mode s...

Page 15: ...icate lights will turn orange color into green color Remove the adaptor when charging finished and over time charging will cause permanent damage 3 You must use the charger adapter supplied with the indicator 4 If after recharging and the battery does not last long replace with new battery Work mode Connect the 4 scales to its corresponding indicator indicator s FRONT LEFT socket connect to RONT L...

Page 16: ...l place the race car smoothly the display will show each wheel s weight front rear left right weight and percentage NOTE 1 If the indicator displays Link it means that the Bluetooth connection failed Please check whether the corresponding scale s Bluetooth indicate light is flashing or light constantly If the indicate light is on please restart the scale 2 If the indicator displays Link and the co...

Page 17: ... will show CALu press UNIT key to select calibration unit kg or lb 3 Press ZERO key the display will show CAL Xxx x press UNIT and ZERO key to enter setting calibration weight press UNIT key to move the flash digit to right press ZERO key to increase the flash digit press ON OFF key to confirm the selection the calibration weight should be more than 1 2 of full capacity CAL0 0 Press UNIT key the d...

Page 18: ...d to the power supply during the work by a third party See Section 1 3 above regarding IP65 The scale may be washed down Never use solvents acids alkalis paint thinners scouring powders or other aggressive or corrosive chemicals for cleaning these substances can cause damage to the surfaces of the scale housing Transportation Storage Your weighing machine is a precision instrument treat it careful...

Page 19: ...o us After the product is received we will inspect it and as necessary we will repair or replace and will ship the product back to the customer at our expense Any new scales returned for warranty must be properly packaged in the original box If they are not properly packed an in the original box the customer pays for shipping cost If we determine there is a factory defect we will pay for the shipp...

Reviews: