QUANTUM NXT DI HEATER OPERATION / MAINTENANCE MANUAL
PAGE 23
Figure 3-5b: USB Historical Plot Page
3.5.e Configuration Page
Figure 3-6: Configuration Page
The configuration page shows a summary of system information, and
allows changes to some of the heater settings as described throughout
this section. The values that are white can be edited. Values that are
grey cannot. If grey values must be changed contact Trebor.
Alarm Delay Setting
Press the delay value to set the pressure and liquid level alarm delay.
Enter the desired alarm delay in seconds and press enter. The default
value is 10 seconds.
Ambient Temperature (Inlet Fluid Temperature) Setting
Setting the ambient fluid inlet temperature allows the heater to more
accurately apply the correct amount of power, maximizing precision.
Touch the value to change the ambient inlet fluid temperature. The
default value is 14°C.