2472 DI HEATER OPERATION / MAINTENANCE MANUAL
PAGE 31
8
TROUBLESHOOTING
The following is an outline of routine troubleshooting techniques. Consult
Trebor for further conditions not covered in this section.
8.1 TEMPERATURE CONTROLLER DOES NOT DISPLAY
CAUSES
SOLUTIONS
EMO button engaged
Twist EMO in direction of arrows (refer
to Section 2.4).
No power at main circuit breaker
Review wiring procedure (see Section
3, Installation).
Main Breaker to ON.
Panel Interlock Switch
Refer to Section 2.3.d, Panel Interlock
Switches.
8.2 ALARM SOUNDS
CAUSES
SOLUTIONS
Over temperature
Check that temperature process value
does
n’t exceed 90°C (review setpoint
procedure).
Check Temperature Controller for
proper operation.
Low pressure
Increase supply pressure.
Reduce flow downstream.
Check overpressure relief diaphragm.
Liquid level
Check water supply at source.
Check overpressure relief diaphragm.
Verify flow is on.
Recalibrate sensor (see Section 7.4).